HSP-...-AP/A S
Festo HSP-...-AP/AS 2017-10b English
9
Fitting: Mechanical components
The HSP-... is supplied ready for fitting.
S
If necessary, remove the protective cover before fitting.
S
Fit first the add-on components and, in the case of the HSP-...-AS, the external
drive or after fastening make sure that there is sufficient free space for fitting
the components.
S
Make sure that the fastening surface can support the weight of the HSP-....
S
Fit the HSP-... only onto a flat fixed surface.
Select one of the following fastening methods:
–
Direct fastening via 4 through holes in the sub-base
[mm]
HSP-12
HSP-16
HSP-24
H1
40
20
40
H2
40±0.2
100±0.2
100±0.2
@
D1
6.3
6.3
6.3
L1
200±0.6
280±0.6
370±0.6
–
Fastening via the side plates
(user-specific hole pattern).
–
Fastening on the rear of the sub-base with
– sliding blocks type HMBN-5-M5
(Fig. 8) or
– fastening kit type HMBK-ND and
connecting bracket type HMBV-ND
(example: Fig. 9).
Fig. 7
D1
L1
H2
H1
Fig. 8