HSP-...-AP/A S
Festo HSP-...-AP/AS 2017-10b English
15
Fitting: Pneumatic components
Connecting the drive for type HSP-...-AP:
S
Use one-way flow control valves of type
GRLA-... for setting the swivel speed. The
speed will be reduced by the throttling of
the exhaust air.
S
Screw in both one-way flow control valves
on the drive.
S
Connect the tubing of the drive.
Connecting the add-on components:
Installation kit MKRP-.. (see chapter “Accessories”) enables the tubing and cables
to be grouped together in a flexible installation tube. The installation tube is fas
tened to the cross guide with the support, and e.g. to the sub-base or the struc
ture with the adapter bracket. The installation tube may be filled to max. 70 %.
Make sure that the moving pneumatic tubing
and electric cables are laid correctly (example
Fig. 18):
S
Lay the cables and tubing upwards along
the vertical guide rail.
S
Fasten the cables and tubing with cable
binders
– on the support of the universal adapter
(A) or pass them through the two cable
channels of the universal adapter (B).
– on the cable binder support (C) on the
cross guide.
S
Pass the cables and tubing through the
holes in the sub-base (E) or use protective
tubing (D).
Fig. 17
Fig. 18
(A)
(B)
(C)
(D)
(E)