4
Commissioning
32
Festo – P.BE-CPX-CTEL-EN – 1601b – English
4.6
Parameters
The CTEL master module can be adapted to the respective situation by using various parameters. In ad
dition, read-only parameters are available for reading out system statuses.
4.6.1
Overview of module parameters
The following table includes an overview of the user-relevant module parameters.
The default settings are shown in
bold
.
Relative
Address
Mod. par.
R/W Bit
Module parameter
7
6
5
4
3
2
1
0
0
RW
X
Monitoring U
OUT
/U
VAL
0 = inactive
1 = active
6
RW
X
X
X
X
Error control per I-Port:
I-Port 1 configuration
I-Port 2 configuration
I-Port 3 configuration
I-Port 4 configuration
00=Use existing device
01 = Expect device
10 = Port inactive
7
RW
X
S
2
.
1
S
2
.
2
S
1
.
1
S
1
.
2
Behaviour after I-Port short cir
cuit.
0 = Leave switched off
1 = Switch on again
CTEL I/O mode
00 = reserved
CTEL I/O length
00 = 2 bytes per I-Port
01 = 4 bytes per I-Port
10 = 6 bytes per I-Port
11 = 8 bytes per I-Port
These parameters are read out only during initialisation of the CTEL master module. Subsequent changes of the parameters have
no effects. Bits 0 ... 3 cannot be written in combination with the Festo Maintenance Tool and the operator unit. They are represen
ted in the online mode as read-only parameters.
with fixed length