2. Assembly
22
Festo GDCP-CMXR-C2-HW-EN 1002NH
The slots in the central control unit are intended for the following optional modules; the
modules only fit exactly in these slots:
Slot
Identification on the
central control unit
Permissible
optional modules
Description
Left slot
[X3] Serial interface
CECX-C-S1
RS-232-C connection (optional)
Middle slot
[X4] CAN
CECX-F-CO
CAN connection
Right slot
[X5] Ethernet
ETHERNET
Ethernet connection
Table 2.1 Assignment of slots
Detailed information on optional modules can be found in the
respective, associated description.
2.2.2
Assembling peripheral modules
Caution
Sub-assemblies and modules may be damaged if they are not
handled correctly.
Switch off the supply voltages before you mount or remove the
peripheral modules.
Do not touch any components.
Observe the handling specifications for electrostatically
sensitive devices.
To protect the modules against discharges of static electricity:
Discharge yourself of static electricity before fitting or removing
the modules.
Peripheral modules are normally supplied from the factory with the address setting 0. The
address setting must be checked, and changed if necessary, before assembling the
peripheral modules.
Setting the module address
The address switch is normally located on the right-hand side of the peripheral modules,
under the bottom cover. The address must be set prior to the device being assembled.
The bus plug is located under the top cover (also see description of peripheral module).
Содержание CMXR-C2
Страница 1: ...Controller Description Assembly and installation Type CMXR C2 Description 571 694 en 1002NH 751 509...
Страница 2: ......
Страница 5: ...Festo GDCP CMXR C2 HW EN 1002NH 5...
Страница 30: ...2 Assembly 30 Festo GDCP CMXR C2 HW EN 1002NH 1 End supports Fig 2 8 Securing the device with end supports 1 1...
Страница 56: ...6 Maintenance and care 56 Festo GDCP CMXR C2 HW EN 1002NH...