4. Instructions on commissioning
48
Festo GDCP-CMXR-C2-HW-EN 1002NH
Display during the running up of the boot system and the firmware
7-segment display
Step
1
The power supply is available (Power on), the module's hardware is
initialised.
2
The consistency of the boot block is tested.
3
Power on self-test, consistency of the module is tested.
4
The firmware is loaded from the memory card into the DRAM.
5
The firmware is started.
6
Running up of the boot block is completed. The operating system is
initialised and started.
7
Various firmware components (services, I/O system, communication) are
started.
8
Autostart query: Factory setting = Automatic start is switched on (if the
Automatic start function was deactivated, then at this point a press of the
CTRL-key is required).
9
Running up of the firmware is completed. The CP module is now ready to
operate. If an application is already present on the memory card, this will
now be loaded.
Table 4.1 Display during running up of the firmware