4. PLC interface MCP1
Festo GDCP-CMXR-F-EN 0909a
15
MCPIO2
Signal
Name
Function
Control
sovereignty
required
Description
DO:0
--
DO:1
--
DO:2
--
DO:3
--
DO:4
ACK
Load the program/Start
executed
No
DO:5
NACK
Load the program/Start not
executed
No
DO:6
RUNNING
Program is running
No
DO:7
LOADED
Program is loaded
No
DI:0
PRGNR Bit0
Selection of program no.
Yes
DI:1
PRGNR Bit1
Selection of program no.
Yes
DI:2
PRGNR Bit2
Selection of program no.
Yes
DI:3
PRGNR Bit3
Selection of program no.
Yes
DI:4
STOP
Interrupt program
Yes
DI:5
START
Start/continue program
Yes
DI:6
UNLOAD
Unload the program
Yes
DI:7
LOAD
Load the program
Yes