![Festo CMMS-ST-*-G2 Series Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/festo/cmms-st-g2-series/cmms-st-g2-series_assembly-and-installation-manual_2283131081.webp)
4. Functional safety engineering
Festo.P.BE-CMMS-ST-G2-HW-EN 1008NH
81
Safety function as per
EN 61800-5-2
PILZ* component
Switch-off behaviour Stop category as
per
EN 60204-1
STO Safe
torque off PNOZ X2P
(Relay outputs forced:
– 2 safety contacts no
delay
Connection options for:
– EMERGENCY OFF
pushbuttons
– Protective door limit
switches
– Start button)
0
SS1
Safe Stop 1
PNOZ XV2P
(Relay outputs forced:
– 2 safety contacts no
delay
– 2 safety contacts
relapse delayed
Connection options
identical to X2P;
Fixed or adjustable
relapse delay;
Cancelling the time delay
via Reset button)
1
*or comparable safety switch device with corresponding safety contacts
Table
4.2 Overview of the safety function in accordance with EN 61800-5-2
An overview of the various stop categories is provided by the Table
Stop category
Type
Handling
0
Uncontrolled shutdown through
immediate switching off of the energy.
EMERGENCY OFF or EMERGENCY STOP
1
Controlled shutdown through switching
off of the energy when a standstill has
been reached.
EMERGENCY STOP
2
Controlled shutdown without switching
off the energy in standstill.
Not suitable for EMERGENCY OFF or
EMERGENCY STOP
Table
4.3 Stop categories