![Festo CMMS-ST-*-G2 Series Скачать руководство пользователя страница 124](http://html1.mh-extra.com/html/festo/cmms-st-g2-series/cmms-st-g2-series_assembly-and-installation-manual_2283131124.webp)
8. Service functions and error messages
124
Festo.P.BE-CMMS-ST-G2-HW-EN
1008NH
Error message
Main
index
Sub-
index
Meaning of error
message
Measures Error
reaction
21
0
Fault in offset current
measurement
Error cannot be self-corrected.
Send the stepping motor controller to the
manufacturer.
PS off
0 PROFIBUS:
Faulty initialisation
Expansion module defective?
Please contact Technical Support.
PS off
1)
22
2 Communication fault
PROFIBUS
Check set slave address
Check bus connection
Check cables
PS off
1)
25
1
Hardware error
Motor controller and firmware are not
compatible.
Update the firmware.
PS off
26 1 Checksum
error
Error
cannot be self-corrected.
Please contact Technical Support.
PS off
0
No SD
Tried to access missing SD card.
Warn
1)
1
SD initialisation error
Error on initialisation
communication not possible.
PS off
1)
29
2
SD parameter record error Checksum incorrect
File missing
Incorrect file format
Error when saving the parameter file to the
SD card
PS off
1)
0
I²t motor (I²t at 100%)
I²t monitoring of the motor has responded;
motor/mechanical system blocked or
sluggish?
Warn
1)
31
1
I²t controller (I²t at 100%) I
²
t monitoring of the controller has
responded. Check power dimensioning of
drive package.
PS off
1)
35
1
Timeout for quick stop
The parameterised time for quick stop was
exceeded
PS off
0
Fault: SW limit switch
reached
Negative software limit switch reached.
1
Fault: SW limit switch
reached
Positive software limit switch reached.
2
Fault: SW limit switch
reached
Target position is behind the negative
software limit switch.
40
3
Fault: SW limit switch
reached
Target position is behind the positive
software limit switch.
Warn
1)