3. Product description
62
Festo.P.BE-CMMS-ST-G2-HW-EN
1008NH
3.5.11
Error messages
The following conditions are monitored for safe operation of the CMMS-ST:
-
End stage temperature,
-
Intermediate circuit voltage to minimum and maximum value,
-
Initialisation errors,
-
Check-sum error on parameter transfer,
-
Communication error,
-
Contouring error (with increment generator only)
-
Homing run,
-
Overload current / short circuit in the power end stage,
-
Encoder system,
-
Watchdog (processor monitoring).
All error messages are documented in chapter
3.5.12
Behaviour when switching off enable
Controller
enable
Drive is moving
1
0
1
0
1
0
1
0
Holding brake
Current-carrying
1
0
DOUT: READY
Output stage
release
1
0
tx
Motor controlled
ty
tx
= x ms (dependent on brake ramps)
ty
= x ms (dependent on set switch-off delay)
Fig.
3.7 Behaviour when switching off controller enable