![Festo CMMS-ST-*-G2 Series Скачать руководство пользователя страница 113](http://html1.mh-extra.com/html/festo/cmms-st-g2-series/cmms-st-g2-series_assembly-and-installation-manual_2283131113.webp)
6. Electrical installation
Festo.P.BE-CMMS-ST-G2-HW-EN 1008NH
113
6.4.10
Field bus settings and boot loader
DIP switches
Meaning
1 ... 7
Node number
8
Boot loader (If the switch is set to ON, the system searches for new firmware on the
SD card)
9
10
Baud rate
11
Activation of the CAN interface
12 Terminating
resistor
Table
6.15 Assignment of the DIP switches
DIP switches
ON / OFF
Meaning
1 ON
2 ON
3 OFF
4 ON
5 ON
6 OFF
7 ON
DIP switch 1 is the lowest bit. 1011011=91
Table
6.16 Sample node number
DIP switches
ON / OFF
Meaning
9 ON
10 OFF
Dip switch 9 is the low-value bit.
00=125 kBaud
01=250 kBaud (example)
10=500 kBaud
11=1000 kBaud
Table
6.17 Sample baud rate