background image

Technical specifications 

Type

DSM-6-...-P

DSM-8-...-P

DSM-10-...-P

Part no.

173 188, 173 189

173 190, 173 191

173 192, 173 193, 173 194

Design

With double-acting swivel vane

Medium

Filtered (40 

µ

m) compressed air, lubricated or non-lubricated

Fitting position

As desired

End position cushioning

Elastic cushioning

Operating pressure range

3 ... max. 8 bar

2.5 ... 8 bar

Temperature range

0 ... + 60° C

Torque at 6 bar

0.15 Nm

0.35 Nm

0.85 Nm

Max. permitted mass moment of inertia on drive shaft (unrestricted)

0.05 x 10

-4

 kgm

2

0.1 x 10

-4

 kgm

2

0.2 x 10

-4

 kgm

2

Max. permitted longitudinal force on drive shaft

10 N

10 N

10 N

Max. permitted lateral force on drive shaft

15 N

20 N

30 N

Minimum radius for stop point with external stop

10 mm

10 mm

13 mm

Max. permitted stop force at external stop

15 N

30 N

60 N

Max. swivel time with

DSM-...-90-P  with swivel angle 90°
DSM-...-180-P with swivel angle1 80°
DSM-...-240-P with swivel angle 240°

1 sec.
2 sec.
3 sec.

Swivel angle with

DSM-...-90-P
DSM-...-180-P
DSM-...-240-P

90° + 5°
180° + 5°

90° + 4°
180° + 4°

90° + 4°
180° + 4°
240° + 4°

Max. cushioning angle

0.5

Max. permitted frequency

2 Hz (with DSM-...-240-P), 
3 Hz (with DSM-...-90-P and DSM-...-180-P)

Weight (approx.)

0.045 kg

0.078 kg

0.14 kg

Materials: 1. housing, 2. shaft/screws, 3. seals

1. Al, elox., 2. St, 3. Polyurethane

Fig. 24

9703 NH

D/GB 19

Содержание 155948

Страница 1: ...und Inbetriebnahme nur von autorisiertem Fachpersonal gem Bedienungsanleitung Fitting and commissioning to be carried out by qualified personnel only in accordance with the operating instructions Es...

Страница 2: ...connections 1 1 2 3 4 5 Durchgangsbohrungen zur Befestigung Druckluftanschl sse Vierkant Abtriebswelle Gewindebohrungen zur Befestigung 1 2 3 4 5 Through holes for fastening Compressed air connection...

Страница 3: ...operating instructions are supplied with the DSM when it is to be extended using one of the above mentioned kits Funktion und Anwendung Durch wechselseitige Bel ftung der Druckluftanschl sse schwenkt...

Страница 4: ...ctions Voraussetzungen f r den Produkteinsatz Allgemeine stets zu beachtende Hin weise f r den ordnungsgem en und si cheren Einsatz des Produkts Ber cksichtigen Sie die angegebe nen Grenzwerte f r z B...

Страница 5: ...You will then avoid extra costs in curred as a result of remedial measures Die Entsorgung der einzelnen Werk stoffe in Recycling Sammelbeh lter ist m glich Behalten Sie die einmal gew hlte Zu sammense...

Страница 6: ...inition bewegliche Masse Nutzlast Masse etwaiger Hebel Bei Verwendung des Vierkants f r optio nale Zwecke Fitting Mechanical Always handle the DSM so that no damage can occur to the drive shaft This a...

Страница 7: ...eger und Ma ssen am Vierkant sollten in der Rech nung mitber cksichtigt sein 3 Avoid lateral forces on the square This serves only as a connecting el ement for the extension modules of types WSM and K...

Страница 8: ...Legende Y kgm2 x 10 4 Massentr gheits moment X sec Schwenkzeit Key to diagram Y kgm2 x 10 4 Mass moment of inertia X sec Swivel time Bild 11 Fig 11 DSM 9703 NH D GB 8...

Страница 9: ...hen den einzelnen Schwenkbewe gungen bei der Notwendigkeit genauer Schwenkwinkel Einstellung 5 Push the moveable mass onto the drive shaft 6 Make sure that the moveable mass cannot slide down from the...

Страница 10: ...ender Zusammenhang zwischen Geschwin digkeit und Drosselweise besteht If external stops and shock absorbers are used make sure that the following specifi cations are observed the point of impact in th...

Страница 11: ...uckabfall ver meiden Sie damit da die bewegli che Masse pl tzlich nach unten schl gt Restricted air flow connection Supply air Exhaust air Supply and ex haust air Speed du ring swivel range in creasin...

Страница 12: ...lag Ventile zun chst ganz zu dann wieder etwa 1 2 Umdrehung auf Commissioning Complete system Slowly pressurize the complete sy stem This is to prevent any uncontrolled movements The safety start up v...

Страница 13: ...gew nschte Schwenkgeschwindigkeit eingestellt ist Der interne Schwenkfl gel soll die Endlage sicher erreichen aber nicht hart anschlagen 3 Make sure that the operating conditions are within the permit...

Страница 14: ...ge nannten Ursachen 10 Wiederholen Sie den Probelauf Bei erfolgter Ausf hrung aller notwendi gen Korrekturen 11 Beenden Sie den Probelauf If the impact is too sudden the swi vel vane will bounce back...

Страница 15: ...m weichen Lappen Zul ssige Reinigungsmedien sind alle werkstoffschonende Medien z B warme Seifenlauge bis 60 C Operation Make sure that nobody can place his her hand in the swivel range of the moveabl...

Страница 16: ...urservice wenn Sie die M glichkeit einer berholung Ihres DSM nutzen wollen Dismantling and repairs If there are eccentric masses on the le ver arm make sure that the mass has re ached a stable positio...

Страница 17: ...er verwenden nur gegen Restluftpolster der Abluftseite fahren kleinere Masse w hlen Bild 23 Eliminating faults Fault Possible cause Remedy Uneven movement of the moveable mass Restrictors inserted inc...

Страница 18: ...L ngskraft auf der Abtriebswelle 10 N 10 N 10 N Max zul ssige Querkraft auf der Abtriebswelle 15 N 20 N 30 N Mindestradius f r Anschlagpunkt bei externem Anschlag 10 mm 10 mm 13 mm Max zul ssige Ansch...

Страница 19: ...0 4 kgm2 Max permitted longitudinal force on drive shaft 10 N 10 N 10 N Max permitted lateral force on drive shaft 15 N 20 N 30 N Minimum radius for stop point with external stop 10 mm 10 mm 13 mm Max...

Страница 20: ...anical photocopying or otherwise without the prior written permission of Festo KG We reserve the right to make altera tions Accessories Designation Type Safety start up valve MFHE VLHE Flow control va...

Отзывы: