2.6 Cable Installation
Section 2: Installation
CV-6SLX User Manual
0101-8242-0, Rev. C
2-8
2.6.1 Connecting the Input Power Cables
Connecting the Power Module Input Power Cable
CAUTION
Make sure that the main power breaker on the HVPS front panel is in the OFF
position and remains in that position throughout the installation procedure.
The CV-6SLX is available for the following input voltages:
•
208-V Model CV-6SLX (PN 6024-7110-0), 50/60 Hz, 3-Phase delta, 4-wire
Connect using AWG #10 stranded UL1015 wire
•
400-V Model CV-6SLX (PN 6024-7120-0), 50/60 Hz, 3-Phase wye, 5-Wire with neutral
Connect using AWG #12 stranded UL1015 wire
The input power cable is user supplied and must conform to the specifications listed above.
On 208-volt units, connect the input power cable as shown in Figure 2-6. On 400-volt units,
connect the input power cable as shown in Figure 2-7. Then plug the input power terminal
connector into the terminal strip on the HVPS rear panel and secure it with the screws
provided for that purpose.
Figure 2-6 Input Power Connections to 208-Volt HVPS Units
Figure 2-7 Input Power Connections to 400-Volt HVPS Units
Содержание Temescal CV-6SLX
Страница 4: ...CV 6SLX User Manual ii 0101 8242 0 Rev C...
Страница 16: ...1 5 TemEBeam Controller EBC Section 1 Introduction to the CV 6SLX CV 6SLX User Manual 0101 8242 0 Rev C 1 4...
Страница 34: ...2 6 Cable Installation Section 2 Installation CV 6SLX User Manual 0101 8242 0 Rev C 2 18...
Страница 90: ...5 5 FPS Fuse Replacement Procedure Section 5 Troubleshooting CV 6SLX User Manual 5 32 0101 8242 0 Rev C...
Страница 92: ...Appendix A Pinout Table for Rear Panel Diagnostic Port J3 CV 6SLX User Manual A 2 0101 8242 0 Rev C...