Nosepiece

Mechanical 

Stage

Fein 

Microscope Components

2

Lock Screw

Fixed Koehler 

Illumination

Focus Arm

Trinocular Head

Vertical 

Adjustment 

Knob

Horizontal 

Adjustment 

Knob

Power Switch

Light 

Adjustment 

Knob

Содержание RB20-HD

Страница 1: ...Fein RB20 Biological Microscope User s Manual info feinoptic com...

Страница 2: ...Fein Microscope Components Eyepieces Condenser Objective Lens 1 Coarse Adjustment Fine Adjustment Tension Adjustment Microscope Frame Carrying Handle Condenser Adjustment Knob...

Страница 3: ...epiece Mechanical Stage Fein Microscope Components 2 Lock Screw Fixed Koehler Illumination Focus Arm Trinocular Head Vertical Adjustment Knob Horizontal Adjustment Knob Power Switch Light Adjustment K...

Страница 4: ...ck 1 and the frame at the front 2 as shown in the image at right Set the power switch to off O before replacing a bulb or fuse and wait until the lamp is cool The power switch is located on the side o...

Страница 5: ...4 Fein Microscope Assembly Follow the numbers below when assembling the microscope Eyepiece Condenser Objectives Power Cord 1 2 3 4...

Страница 6: ...il the condenser is aligned with the base and rotate the condenser to make the handle face forward Tighten the condenser lock screw 2 of condenser then raise the condenser with the up down knob to the...

Страница 7: ...ntil the eyepiece is flush with the eyepiece tube Tighten the eyepiece with M2 5 inner hexagon lock screw 3 1 3 2 Assemble the Eyepiece Take off the eyepiece tube cover 1 Insert the eyepiece 2 into th...

Страница 8: ...wly move the specimen holder lever back into place This will secure the specimen slide Rotate the X and Y axis knobs 3 on the stage until the center of the specimen slide is aligned with the objective...

Страница 9: ...e eyepieces 2 to fit your personal interpupillary distance The scale between the eyepieces 1 notes the interpupillary distance setting It s a good idea to note this number when working in a setting wh...

Страница 10: ...r use wipe the lens with a tissue moistened with microscope cleaning solution Using Filters Filters can increase the contrast in microscopy images The filter sits on top of the light as shown at the r...

Страница 11: ...e microscope is not in use the power cord can be placed in the storage box Press the position 1 of the storage box cover with thumb When you hear a click push up and put the power cord into the storag...

Страница 12: ...over glass The cover glass is not standard Use a standard cover glass with thickness of 0 17mm The slide is upside down Adjust the slide The immersion oil has accumulated on the dry objective Clean th...

Страница 13: ...xed correctly Adjust it The movable specimen holder is not fixed properly Adjust it The image moves obviously when touching the stage The stage is fastened incorrectly Fasten the stage correctly The L...

Страница 14: ...rrying handle side is down Locate the 4 rubber feet on the underside of the microscope Remove the rubber feet exposing the 4 screws securing the bottom plate of the microscope Gently lay microscope on...

Страница 15: ...th all 4 screws removed carefully remove the bottom plate exposing the internal components of the microscope Locate the 2 screws securing the LED bulb in place Using a screw driver remove the 2 screws...

Страница 16: ...the LED bulb replaced position the bottom of the microscope plate back onto the microscope frame Using a screw driver secure the bottom plate with the 4 set screws Place the 4 rubber feet over the to...