OPERATION MANUAL 

STEREO ZOOM  

MICROSCOPE 

MSC41-060ST  

Summary of Contents for MSC41-060ST

Page 1: ...OPERATION MANUAL STEREO ZOOM MICROSCOPE MSC41 060ST...

Page 2: ...us 4 5 9 Adjust the interpupillary distance 4 6 9 Use Eyepiece shields 4 8 9 Install the illumination device 4 9 10 Choose the optical system 4 10 10 Mount the photo eyepiece and the PK mount adapter...

Page 3: ...s must be kept clean Fine dust on the surface of the lens should be blown off with hand blower or wiped off gently with a soft lens tissue Fingerprints or oil marked on it should be wiped off with a t...

Page 4: ...tac com 4 STEREO ZOOM MICROSCOPE Head Eyepiece shield Eyepiece Diopter adjust ring Lock screw Glass stage Clip Bracket Focusing knob Illumination device Base Fuse Bottom variable light control Bottom...

Page 5: ...ww labstac com Base Bracket Photocube Illumination device Focusing knob device Eyepiece shield Eyepiece Diopter adjust ring Glass stage Head Lock screw Clip Top variable light control Bottom variable...

Page 6: ...3 Assemblage www labstac com 6 STEREO ZOOM MICROSCOPE...

Page 7: ...PK mount adapter Photo eyepiece Eyepiece shield C mount Eyepiece Illumination device Head Clip Glass stage Base 7 STEREO ZOOM MICROSCOPE www labstac com...

Page 8: ...is tight otherwise is loose 2 The suitable position of the tightness can make the adjustment more comfortable and prevent the focusing bracket from slipping down by its weight during the observation 2...

Page 9: ...Turn and remove the mounting ring from the eyepiece 5 Fig 2 Clean the eyepiece micrometer and mount it to the mounting ring with the inscription side downward 3 Gently twist the mounting ring with the...

Page 10: ...light 1 Turn the adjustable light knob according to the sign marked on the base along the clockwise the brightness will 9 be added otherwise it will be weakened Fig 4 12 Fig 11 4 12 Replace the lamps...

Page 11: ...1 100 X mm 2 100 X mm 3 100 X mm 4 100 X mm Binocular 60 ST Tri ocular 60 ST TR Big conversion lens 0 5 165 SZMAO mm 1 5 45 SZMAO m m 2 30 SZMAO m m Focusing arm 1 SZMA Stand 1 SZMST 2 SZMST 3 SZMST 1...

Page 12: ...www labstac com 12 STEREO ZOOM MICROSCOPE...

Page 13: ...fixed regardless of the magnification factor Total mag Objective mag X Auxiliary mag X Auxiliary mag Eyepiece field Diameter of field of view mm Objective mag X Auxiliary objective mag Photo adaptor m...

Page 14: ...eyepiece tube 54 75 Range of single adjustment mm Diopier adjustment Range of single adjustment 5D Mount with auxiliary objectives Screw hole 48 0 75 M Objecti ve Field of view 20mm Main body Mount th...

Page 15: ...Loosen it to a suitable position 6 The image is obscure because of the head slipping down by itself during observation The focusing knob is too loose Tighten it to a suitable position 7 Incision image...

Page 16: ...12 The bulb flickers or the brightness is unstable The bulb will burn out soon Replace with a new one The bulb was not inserted correctly Insert it correctly www labstac com 16 STEREO ZOOM MICROSCOPE...

Page 17: ...Email contact labstac com Website www labstac com 17 STEREO ZOOM MICROSCOPE www labstac com...