TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 95 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
Relay outputs
If inductive loads are connected (for example, additional
relays or brakes), these must be quipped with the
appropriate suppression measures (freewheeling diode,
varistors, RC elements)
Relay K1 and K2
Changeover contact free of
potential
min. 10 mA
max. 230 VAC / 3 A
Contacts used once for
circuit breakers cannot
switch further low
currents.
Digital Output OUT15
Controller variants -B / -C / -CX
/ -CGH / -CXGH / -LGH
24 VDC / min. 10 mA / max. 120 mA
General application: All types of resistive, iinductive and
capacitive loads in industrial applications
Drive output
Controller variants
-A / -B / -C/ -CGH
Controller variant -CS
for drives up to 0.75 KW at 230 V
Constant motor current at 100% duty cycle and 40 °C
surrounding temperature: 3 A
Motor current at 40% duty factor and 50°C ambient
temperature: 5 A
Max. length of motor cable: 30 m
Overload for 0.5 s: 10 A
29 minutes for continuous operation at 40 °C
10 % duty cycle at 40 °C
Drive output
Controller variants -CX / -CXGH
Controller variant -CXS
for drives up to 1.2 kW at 230 V
Constant motor current at 100% duty cycle and 40 °C
surrounding temperature: 5 A
Motor current at 40% duty factor and 50°C ambient
temperature: 8 A
Max. length of motor cable: 30 m
Overload for 0.5 s: 16 A
29 minutes for continuous operation at 40 °C
10 % duty cycle at 40 °C
Drive output
Controller variant -LGH
Controller variant -LS
for drives up to 1.5 kW at 230 V
Constant motor current at 100% duty cycle and 40 °C
surrounding temperature: 8 A
Motor current at 40% duty factor and 50°C ambient
temperature: 10 A
Max. length of motor cable: 30 m
Overload for 0.5 s: 20 A
29 minutes for continuous operation at 40 °C
10 % duty cycle at 40 °C
Brake chopper and resistor
Controller variants
-C / -CX / -CGH / -CXGH / -LGH
Max. 1.5 kW for max. 0.5 seconds
repetition rate min. all 20 seconds
The heatsink / brake resistor on the back of the
housing can reach temperatures up to 85° C. In case of
failure this may briefly reach 280 ° C
(< 5 Min.)!
Temperature operating range
-
20…+50°C
Maximum 40 °C in steel and stainless steel housing!
Temperature storage range
-
20…+70°C
Humidity
up to 95% non condensing
Noise Emission
<20 dB (A)