FUZ2 -A/-B/-C/-CX/-G/-L
Assembly instructions
TST
FEIG ELECTRONIC GmbH
Page 80 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
No.
Description
Possible reason for error
F.369
Internal safety edge incorrectly
parameterized
• An internal safety edge is connected but deactivated → set P.460 to the used edge type
F.371
Number of trips of the Safety
input E, normally this is the
integrated safety edge
evaluation, has reached set
limit (configurable in P.47E)
• Parametrized, maximum number of trips of the safety input E during a door cycle was exceeded → To reset close
the door in jog mode
• Check the set number of reversing trips in P.47E.
F.372
Redundancy error with short
circuit
• One of the processing channels for short circuit detection does not react identically with the second channel.
• Controller board defective
F.373
Fault in the safety edge
(message comes from module)
• Cable break to safety edge, no edge connected, edge termination resistor incorrect or defective
• Jumper for termination resistor definition in wrong position.
• Safety edge processing selected with Parameter P.470, but module not plugged in or wrong module.
F.374
Safety edge testing failed
• Pre-limit switch for safety edge incorrectly set or defective
• Processing module defective
• Safety edge defective
F.379
Safety edge detection defective
(coding pin or parameter
setting)
• No module plugged in but was reported as present by a parameter
• The controller was started up with another module than the one currently plugged in
F.37A
Redundancy error of the 8K2
slip door switch on the internal
safety edge evaluation unit
channel 1
• One of the contacts of the redundant 8k2 slip door switch is defective
• The slip door was not fully opened or closed
F.380
Short circuit detected on safety
input
• Short circuit detected on edges with normally closed contact
F.383
Interruption on safety input
• Connection cable defective or not connected
• Termination resistor incorrect or missing
• Jumper incorrectly set
F.384
Safety input testing failed
• Safety edge was not activated as expected when requesting a test.
• The time between request for testing and actual testing not in agreement
F.385
Fault in pre-limit switch for
safety edge
• Pre-limit switch for turning off the safety edge or reversing after safety edge tripping remains tripped even in the
upper end position.
F.386
Too high a pulse frequency for
optical safety edge
• Faulty optical safety edge
• Defective input for internal safety edge
F.389
Safety input incorrectly
parametrized
• A safety edge is connected but deactivated
Safety input Jumper incorrectly set (as digital input jumpered but as safety edge set)