TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 75 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
No.
Description
Possible reason for error
F.033
Bad position transmitter
protocol
• Fault on the position transmitter
• No position data available over an extended period
F.043
Pre-limit switch fault (light
barrier)
• The pre-limit switch for the light barrier remains activated even in the middle end position or upper end position.
F.060
Breakaway recognized
• Breakaway was detected but not fixed
• The automatic lead in after breakaway has failed
F.063
Balance error on loop 3
• Disturbed environment
• Loop outside the tolerance range
F.064
Balance error on loop 4
• Disturbed environment
• Loop outside the tolerance range
F.067
Error on loop 3
• Shortcut or intermitted loop connection wirering
F.068
Error on loop 4
• Shortcut or intermitted loop connection wirering
F.080
Maintenance is required
• Service counter has expired
F.090
Controller not parameterized
• The min. necessary basic parameters for the controller have not yet been set → Activate DIP-switch and put in the
asked parameters.
F.101
Message from sensor-actor-
interface:
An unknown or incompatible
device was detected on the
CAN or RS485 bus. The
controller is not able to identify
it and assign it to a device class
(detector, light curtain, etc.).
• The serial number of the connected device is not known --> Replace device.
• The software version or protocol version is incompatible --> Update the control software.
F.102
Faulty CAN bus due to faulty
telegrams.
• Poor CAN wiring
• Missing ferrites on the motor cable
• Missing terminating resistors for CAN bus termination
• CAN lines too long (180m)
• Faults on the CAN line when the door operator is moving
F.103
CAN BUS is faulty. The error
acknowledges itself
automatically if the CAN BUS is
not faulty.
•Short circuit of The CAN Low and CAN High lines
•A device on The CAN bus interferes with The bus due to faulty telegrams.
•non terminated CAN bus
F.104
The maximum number of
permitted devices (16) on the
CAN bus has been exceeded.
There are too many devices on the CAN bus