TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 39 of 96
TST_FUZ2-A-B-C-CX-G-
L_Montageanleitung_EN_22.docx
6.4 Safety edge on the integrated evaluation
Various types of safety edges can be connected, for example:
•
Electrical safety edge with 1.2 kΩ or 8.2 kΩ terminating resistor.
•
Dynamical optical system
If one of these types of safety edges is connected when the door controller is switched on it will
be recognized automatically.
If no safety edge is connected, automatic closing of the door is not possible.
Use of additional types of safety edges is possible. Please contact the door manufacturer in this respect.
6.4.1
Optical safety edge
45
44
43
42
41
Spiral cable
Junction
box
41 42
Slack rope
switch
optional slip
door switch
brown
white
Jumper J 800 is
located to the left
and behind terminal
61 - 62
1
3
J800 = 1-2
8,2K
1,2K
J800
Receiver
Transmitter
green
Figure 18: Connection of an optical safety edge