TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 91 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
14 General messages
General messages
STOP
Stop
/ reset state, wait for next incoming command
_Eu_
Lower limit position
Eu
lower limit position locked
→
raising not possible (e.g., lock-door)
ZUF
@
Closing active
-Eo-
Upper limit position
Eo
upper limit position locked
→
closing not possible (e.g., safety edge)
@
OPE
Opening active
-E1-
middle limit position E1 (intermediate stop position)
E1
upper limit position locked
→
closing not possible (e.g., safety edge)
FAIL
Fault
→
only deadman travel is possible, automatic opening may also be possible
"CALI:
calibration
→
setting the limit positions in deadman travel mode
(for absolute encoder )
→
Start procedure using STOP key
NA
E-STOP
→
Movement not possible, hardware safety chain interrupted
HdSA:
E-travel
→
Deadman travel without regard for safety facilities, etc.
'Hd'
Manual
→
Deadman mode
ParA
Parametrization
SYNC:
Synchronization
(incremental encoder / limit switch
→
Pos.unknown)
'Au'
Automatic
→
indicates change from "Manual" to "Automatic" status
'Hc'
Semi-automatic
→
indicates change from "Manual" to "Semi-automatic"
FUZ.
first display after switching on (Power Up and Self-test)
LOCK
Locked
-> Display after the end of the set time for the virtual key switch
Status messages during calibration
E.i.E.c.:
calibration of the lower limit position requested (in deadman travel)
E.i.E.o.:
calibration of the lower limit position requested (in deadman travel)
E.i.E.1
calibration of intermediate position E1 (in deadman travel)
Status messages during synchronization
S.y.E.c.:
Synchronization of lower limit position requested
(Jog Mode or wait for start command)
S.y.E.o.
Synchronization of lower upper position requested
(Jog Mode or wait for start command)
S.y.E.1.
Synchronization of intermediate stop position E1 (in deadman mode)
S.y.op:
Automatic opening up to mechanical stop, then automatic synchronization of upper limit
position
S.y.cL
Automatic closing taking into account safeties up to mechanical stop, followed by
automatic synchronization of lower limit position
S.y.c
Automatic closing is locked due to request Å
Status messages during dead man movement:
Hd.cL
Deadman closing (membrane key: CLOSE)
Hd.oP
Deadman closing (membrane key: OPEN)
Hd.Eu
Lower limit position reached, no further deadman closing possible
Hd.Eo
Upper limit position reached, no further deadman opening possible
Hd.Ao
Outside of permitted Eo position (no deadman opening possible)
Information messages during the parameter configuration:
noEr
Error memory: no error saved
Er--
Error memory: if error but without associated message being found
Prog
Programming message while carrying out original parameter or default set