23
CX SERIES Installation, Operating & Maintenance Manual
INST
ALLER
ADDITIONAL FEATURES
Settings Page
Some settings specific to the CONTROL can be set
from this page. The aligns with the cleaning time.
This feature disables the touch screen for that period
of time so it can be cleaned. The recalibrates the
touch screen. "Start Mode" determines how the system
starts when a timer is connected. When the start
mode is set to "Steam" the generator will create steam
and heat the the room to the set point for the first 45
minutes of operation, even if the timer is off. When the
start mode is set to standby the system will maintain
the water temperature in the unit but not create steam
until the timer is turned on.
IOM
A digital version of the IOM is available on the
CONTROL
About Page
This page has software information. In addition, if the
system needs to change the number of generators,
that can be done from this page. When multiple gener-
ators are present the “Steam Unit No.” will have toggle
buttons which will allow the user to scroll through the
different software versions of each generator.
AutoFlush Operation:
•
Each time the CX steam generator is turned off
(either manually or by a programmed off time), the
AutoFlush sequence will begin
•
The AutoFlush valve will open to drain the sediment rich water from the tank, and the feed solenoid valve will open
to bring in fresh water to quench the drain water.
•
The system will drain and flush for 10 minutes, after 10 minutes the valve will close and the unit
will
remain empty
until the next time it is started manually or with the timer.
Scalding hazard, the CX unit drains at 140 *F, do not drain into a steam enclosure or any location
where accidental contact with drain water may occur