CX SERIES Installation, Operating & Maintenance Manual

STEAM PIPING (3/4" NPT) 

 

 Do not install any valve in steam 

piping. The flow of steam must be unobstructed. 

 CX Steam Generators must be 

installed with one or more steamheads per generator. 
Two steamheads per generator is recommended and 
will result in reduced noise. For installations of 
tandemed CX Steam Generators, each generator must 
be installed with one or more steamheads. 

 Never use less than 3

4” steam piping 

from generator. Using less than 3/4” steam piping will 
result in increased velocity of steam coming out of 
the steamheads and may result in scalding and 
personal injury. 

 Install steam piping as required 

(including routing, fittings and length of pipe) to 
ensure an equal amount of steam reaches each 
steamhead. Unequal steam piping will result in too 
much steam coming out of one steamhead and may 
result in scalding and personal injury. 

 

 

 Use brass pipe or copper tubing from 

unit to steamhead as permitted by codes.

 

 Insulate steam piping with fiberglass 

pipe insulation or similar insulation rated 212° F or 
higher.

 

 Pitch steam piping 1/4" per foot 

towards steamhead or steam generator to avoid 
valleys and trapping of condensate. Running the 
steam piping down and then up will create a steam 
trap blocking or restricting the flow of steam. 

 Models CX1600 to CX5000 are made of 

multiple steam generators. Each steam generator 
must be plumbed separately to a dedicated steam 
line and dedicated steamhead.

(All Drawings for Illustrative Purposes Only.)

INST

ALLER

3

/

4

” 

Steam Piping

Union 

Safety 

Valve 

Manual Drain 

Valve

External Connections  
Terminal Block 

Tee 

Fitting

AutoFlush

Steam 

Outlet

STEAM 

GENERATOR

STEAM ROOM

SteamHead

Note: 

Some CX systems have multiple generators. 

Each steam generator must be plumbed separately 
to a dedicated steam line and dedicated steamhead.

Содержание mr. steam CX Series

Страница 1: ...tors Installation Operation Maintenance Manual Models CX0360 through CX5000 Installation Operation Maintenance Manual _______________________________________ IMPORTANT LEAVE THIS MANUAL WITH THE OWNER...

Страница 2: ...egulate its internal temperature hyperthermia Limit your use of steam to 10 15 minutes until you are certain of your body s reaction D Excessive temperatures have a high potential for causing fetal da...

Страница 3: ...n 8 Notice 8 Safety Valve 3 4 NPT 8 Warning 8 Caution 8 Steam Piping 10 Steamhead Installation 10 Notice 10 Acrylic Shield 11 Notice 11 Control Mounting 12 Flush Mounting 12 Surface Mounting 12 Electr...

Страница 4: ...or using a steam room Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body s ability to regulate its internal temperature hyperthermia Limit...

Страница 5: ...installation Read the Installation and Operation Manual of all controls and accessories available at www mrsteam com Record the model and serial number of the steam generator in the space provided in...

Страница 6: ...only to prevent damage to the generator pipes and electrical system Failure to install in an upright position may result in a leak or shock hazard Do not hang the CX steam generator on a wall Hanging...

Страница 7: ...use black galvanized PVC pipe or PEX except as noted Water supply and steam piping must be flushed to remove flux and other debris prior to connecting the steam generator Failure to flush the steam p...

Страница 8: ...rain into a steam enclosure or any location where accidental contact with drain water may occur Do not connect the drain valve to the steam piping Connecting the drain line to the steam piping may all...

Страница 9: ...steam coming out of one steamhead and may result in scalding and personal injury Use brass pipe or copper tubing from unit to steamhead as permitted by codes Insulate steam piping with fiberglass pip...

Страница 10: ...LLATION For steam rooms constructed of tile marble or similar non porous heat resistant materials for the enclosure locate steamhead 12 inches above steam room floor and install MsSteam PN 103938 acry...

Страница 11: ...d bottom of the steamhead Place an Acrylic Shield PN 103985 over the steamhead until the tabs engage the grooves in the steamhead Do not use with fragrance containing aldehydes Acrylic Shield damage m...

Страница 12: ...ould be facing down as does the side of the box which is open Insert and tighten each of the 4 provided clips into their respective slots on the sides and top of the control to secure the control to t...

Страница 13: ...ng installation to be performed by a qualified licensed electrician in accordance with National Electrical Code and Local Electrical Code Connect electrical power supply to the power block only Do not...

Страница 14: ...14 CX SERIES Installation Operating Maintenance Manual I N S T A L L E R CONTROL CIRCUIT WIRING DIAGRAM...

Страница 15: ...15 CX SERIES Installation Operating Maintenance Manual I N S T A L L E R POWER CIRCUIT WIRING DIAGRAM...

Страница 16: ...11 280 16 1 2 419 22 578 1 3 8 34 2 3 8 60 7 7 8 200 1 7 8 48 251 8 638 2 3 8 60 6 3 8 162 Dimensions 5 7 8 150 NOTES All units in inches MM TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRE...

Страница 17: ...r cable directly to PLC in the primary generator as shown Do not route sensor cable with power wiring next to electric motors or any other location subject to electrical noise Seal cable entrance to s...

Страница 18: ...le for the end user of the steam generator it was fitted in to remove the timer by pulling it to the front and exposing the live parts Avoid any contact of the timer with water The 30 minute room time...

Страница 19: ...V Single Phase CX0360 29093BMS Heating Element 9kW 208V Three Phase CX0360 29091CMS Heating Element 9kW 240V Single Phase CX0360 29093CMS Heating Element 9kW 240V Three Phase CX0360 29121BMS Heating E...

Страница 20: ...rnet port on the right side of the first generator as well as the ethernet port on the router 2 Take another of the provided cables and connect it to the ethernet port on the bottom of the CONTROL as...

Страница 21: ...Start Stop Time 9 There are 7 available settings which can be toggled through using the arrows on the upper right For each desired setting select the days which is applies to and the start and stop ti...

Страница 22: ...e seen in the bottom right corner of every screen Green and White indicates a normal con dition Orange indicates a standby mode Red indi cates an error or off With the Auto Flush white indicates it is...

Страница 23: ...CONTROL About Page This page has software information In addition if the system needs to change the number of generators that can be done from this page When multiple gener ators are present the Steam...

Страница 24: ...rify that 120 VAC is coming out of the transformer BLACK WHITE wires into the circuit board Step 4 Push the manual ON button on the CONTROL to run the gener ator Make sure the steam room is empty Step...

Страница 25: ...Voltage Supply Damage to the 24VDC power supply Replace 24VDC power supply Steam Unit X X Has A Cable Break At Input 1 Room Probe Disconnected Check to make sure the connections are secure Replace cab...

Страница 26: ...90301 1 800 72 STEAM 2021 Mr Steam and des AirTempo AromaFlo AutoFlush AutoSteam AudioWizard Butler Package ChromaSteam Clean Steam Every Time Club Therapy Digital 1 Express Steam From Bathroom to Sp...

Отзывы: