CX SERIES Installation, Operating & Maintenance Manual

INST

ALLER

 

Do not run any control wiring inside 

conduit together with power lines or close to hot 
water or steam piping. Doing so may result in an 
inoperative or hazardous installation. 

Installation or operation of the steam 

generator in an ambient temperature above 113° F (45 °C) 
may result in a hazardous condition or property damage.  

Do not install the steambath generator 

or control inside steam room, a shock hazard and/or 
equipment damage will occur. 

Do not install steambath generator 

outdoors or wherever environmental conditions may 
result in a shock hazard and/or equipment damage. 

To prevent a fire hazard, do not install 

the steambath generator near flammable or corrosive 
materials or chemicals such as gasoline, paint thinners, 
or the like. 

Installation in areas having high 

concentrations of chlorine (such as pool equipment 
room) must be avoided. 
 

 Do not install the steambath generator 

or plumbing line in an unheated attic or any locations 
where water could freeze and cause pipes to rupture 
and cause property damage. 

 

Steam piping, safety valve, drain valve and 

plumbing become hot during operation and remain hot 
after shutdown for a period of time. Provide appropriate 
protection, including insulating plumbing lines. Avoid 
plumbing runs and steamhead locations that can come in 
contact with bathers to prevent a burn hazard. 

 

Install the steambath generator on a 

solid and level surface. 

 

Install the steambath generator in an 

upright position only to prevent damage to the 
generator, pipes and electrical system. Failure to install in 
an upright position may result in a leak or shock hazard. 

 

Do not hang the CX steam generator on 

a wall. Hanging the CX generator on a wall may result 
in a leak, shock hazard or equipment damage. 
 

  Provide a minimum of 18"on the left side 

and 21" at the top of the steam generator or as required 
for servicing. See page 7 for complete information. 

 Select a location as near as practical to the 

steam room.  

 The standard length of the cable for connecting 

the Temperature Probe to the steam generator is 30 feet. The 
steam generator and control must be located accordingly. A 
longer cable can be purchased by the end user. 

 Install anti-water hammer device as necessary. 
 The control cable should be run in a dedicated 

1-inch conduit to facilitate installation and service. 

 Provide unions as required to facilitate 

installation and removal of the steam generator. 

 The minimum clearance from combustible 

surfaces is zero all around. 
 

STEAM GENERATOR CLEARANCE SPECIFICATIONS 

 

Do not install CX series inside a small 

enclosed space . Do not install under the steam room 
bench. Installing the CX steam generator in a small 
enclosed space may result in elevated temperatures 
and an inoperable steam generator. 

 

Locate the CX series generator in a 

room with ventilation as required to prevent an 
increase in ambient temperature. Failure to provide 
adequate ventilation may result in elevated 
temperature and an inoperable steam generator. 
 

 Minimum Clearance from Combustible 

Surfaces is zero all around. 

 For ease of servicing and installation, 

MrSteam recommends a minimum clearance around 
the steam generator as shown. 

LOCATING THE STEAM GENERATOR

Содержание mr. steam CX Series

Страница 1: ...tors Installation Operation Maintenance Manual Models CX0360 through CX5000 Installation Operation Maintenance Manual _______________________________________ IMPORTANT LEAVE THIS MANUAL WITH THE OWNER...

Страница 2: ...egulate its internal temperature hyperthermia Limit your use of steam to 10 15 minutes until you are certain of your body s reaction D Excessive temperatures have a high potential for causing fetal da...

Страница 3: ...n 8 Notice 8 Safety Valve 3 4 NPT 8 Warning 8 Caution 8 Steam Piping 10 Steamhead Installation 10 Notice 10 Acrylic Shield 11 Notice 11 Control Mounting 12 Flush Mounting 12 Surface Mounting 12 Electr...

Страница 4: ...or using a steam room Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body s ability to regulate its internal temperature hyperthermia Limit...

Страница 5: ...installation Read the Installation and Operation Manual of all controls and accessories available at www mrsteam com Record the model and serial number of the steam generator in the space provided in...

Страница 6: ...only to prevent damage to the generator pipes and electrical system Failure to install in an upright position may result in a leak or shock hazard Do not hang the CX steam generator on a wall Hanging...

Страница 7: ...use black galvanized PVC pipe or PEX except as noted Water supply and steam piping must be flushed to remove flux and other debris prior to connecting the steam generator Failure to flush the steam p...

Страница 8: ...rain into a steam enclosure or any location where accidental contact with drain water may occur Do not connect the drain valve to the steam piping Connecting the drain line to the steam piping may all...

Страница 9: ...steam coming out of one steamhead and may result in scalding and personal injury Use brass pipe or copper tubing from unit to steamhead as permitted by codes Insulate steam piping with fiberglass pip...

Страница 10: ...LLATION For steam rooms constructed of tile marble or similar non porous heat resistant materials for the enclosure locate steamhead 12 inches above steam room floor and install MsSteam PN 103938 acry...

Страница 11: ...d bottom of the steamhead Place an Acrylic Shield PN 103985 over the steamhead until the tabs engage the grooves in the steamhead Do not use with fragrance containing aldehydes Acrylic Shield damage m...

Страница 12: ...ould be facing down as does the side of the box which is open Insert and tighten each of the 4 provided clips into their respective slots on the sides and top of the control to secure the control to t...

Страница 13: ...ng installation to be performed by a qualified licensed electrician in accordance with National Electrical Code and Local Electrical Code Connect electrical power supply to the power block only Do not...

Страница 14: ...14 CX SERIES Installation Operating Maintenance Manual I N S T A L L E R CONTROL CIRCUIT WIRING DIAGRAM...

Страница 15: ...15 CX SERIES Installation Operating Maintenance Manual I N S T A L L E R POWER CIRCUIT WIRING DIAGRAM...

Страница 16: ...11 280 16 1 2 419 22 578 1 3 8 34 2 3 8 60 7 7 8 200 1 7 8 48 251 8 638 2 3 8 60 6 3 8 162 Dimensions 5 7 8 150 NOTES All units in inches MM TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRE...

Страница 17: ...r cable directly to PLC in the primary generator as shown Do not route sensor cable with power wiring next to electric motors or any other location subject to electrical noise Seal cable entrance to s...

Страница 18: ...le for the end user of the steam generator it was fitted in to remove the timer by pulling it to the front and exposing the live parts Avoid any contact of the timer with water The 30 minute room time...

Страница 19: ...V Single Phase CX0360 29093BMS Heating Element 9kW 208V Three Phase CX0360 29091CMS Heating Element 9kW 240V Single Phase CX0360 29093CMS Heating Element 9kW 240V Three Phase CX0360 29121BMS Heating E...

Страница 20: ...rnet port on the right side of the first generator as well as the ethernet port on the router 2 Take another of the provided cables and connect it to the ethernet port on the bottom of the CONTROL as...

Страница 21: ...Start Stop Time 9 There are 7 available settings which can be toggled through using the arrows on the upper right For each desired setting select the days which is applies to and the start and stop ti...

Страница 22: ...e seen in the bottom right corner of every screen Green and White indicates a normal con dition Orange indicates a standby mode Red indi cates an error or off With the Auto Flush white indicates it is...

Страница 23: ...CONTROL About Page This page has software information In addition if the system needs to change the number of generators that can be done from this page When multiple gener ators are present the Steam...

Страница 24: ...rify that 120 VAC is coming out of the transformer BLACK WHITE wires into the circuit board Step 4 Push the manual ON button on the CONTROL to run the gener ator Make sure the steam room is empty Step...

Страница 25: ...Voltage Supply Damage to the 24VDC power supply Replace 24VDC power supply Steam Unit X X Has A Cable Break At Input 1 Room Probe Disconnected Check to make sure the connections are secure Replace cab...

Страница 26: ...90301 1 800 72 STEAM 2021 Mr Steam and des AirTempo AromaFlo AutoFlush AutoSteam AudioWizard Butler Package ChromaSteam Clean Steam Every Time Club Therapy Digital 1 Express Steam From Bathroom to Sp...

Отзывы: