CX SERIES Installation, Operating & Maintenance Manual
INST
ALLER
Do not run any control wiring inside
conduit together with power lines or close to hot
water or steam piping. Doing so may result in an
inoperative or hazardous installation.
Installation or operation of the steam
generator in an ambient temperature above 113° F (45 °C)
may result in a hazardous condition or property damage.
Do not install the steambath generator
or control inside steam room, a shock hazard and/or
equipment damage will occur.
Do not install steambath generator
outdoors or wherever environmental conditions may
result in a shock hazard and/or equipment damage.
To prevent a fire hazard, do not install
the steambath generator near flammable or corrosive
materials or chemicals such as gasoline, paint thinners,
or the like.
Installation in areas having high
concentrations of chlorine (such as pool equipment
room) must be avoided.
Do not install the steambath generator
or plumbing line in an unheated attic or any locations
where water could freeze and cause pipes to rupture
and cause property damage.
Steam piping, safety valve, drain valve and
plumbing become hot during operation and remain hot
after shutdown for a period of time. Provide appropriate
protection, including insulating plumbing lines. Avoid
plumbing runs and steamhead locations that can come in
contact with bathers to prevent a burn hazard.
Install the steambath generator on a
solid and level surface.
Install the steambath generator in an
upright position only to prevent damage to the
generator, pipes and electrical system. Failure to install in
an upright position may result in a leak or shock hazard.
Do not hang the CX steam generator on
a wall. Hanging the CX generator on a wall may result
in a leak, shock hazard or equipment damage.
Provide a minimum of 18"on the left side
and 21" at the top of the steam generator or as required
for servicing. See page 7 for complete information.
Select a location as near as practical to the
steam room.
The standard length of the cable for connecting
the Temperature Probe to the steam generator is 30 feet. The
steam generator and control must be located accordingly. A
longer cable can be purchased by the end user.
Install anti-water hammer device as necessary.
The control cable should be run in a dedicated
1-inch conduit to facilitate installation and service.
Provide unions as required to facilitate
installation and removal of the steam generator.
The minimum clearance from combustible
surfaces is zero all around.
STEAM GENERATOR CLEARANCE SPECIFICATIONS
Do not install CX series inside a small
enclosed space . Do not install under the steam room
bench. Installing the CX steam generator in a small
enclosed space may result in elevated temperatures
and an inoperable steam generator.
Locate the CX series generator in a
room with ventilation as required to prevent an
increase in ambient temperature. Failure to provide
adequate ventilation may result in elevated
temperature and an inoperable steam generator.
Minimum Clearance from Combustible
Surfaces is zero all around.
For ease of servicing and installation,
MrSteam recommends a minimum clearance around
the steam generator as shown.
LOCATING THE STEAM GENERATOR