CX SERIES Installation, Operating & Maintenance Manual
INST
ALLER
30 MINUTE ROOM TIMER
The 30 minute timer provides guests in the steam room an
accurate and easy way to safely time their steam sessions. It is
available as a Digital (104560) or Mechanical (CU-99216B) timer.
•
This timer may only be fitted by a qualified electrician.
This timer uses the specific supply voltage. Fit the
timer appropriately before connecting it to the main supply. Never
touch the live contacts or components at the open back of the timer.
•
Protection against touch contact must be ensured by a proper
mounting. When fitting the timer, make sure that during normal
operation it is impossible for the end user of the steam
generator it was fitted in to remove the timer by pulling it to the
front and exposing the live parts.
•
Avoid any contact of the timer with water.
•
The 30 minute room timer shall be installed to the external connection
terminal block. See page 16 for location. The jumper shall be removed as
per the wiring diagram.
•
In the event the CX system has multiple generators, connect the 30 minute
room timer, the emergency stop, and the room probe to generator 1.
•
When connecting the digital timer the timer’s neutral connects to the N
terminal, the timer’s power connects to the L terminal and the switched
circuit from the timer connects to the S terminal. When connecting a
mechanical timer only the L and S terminals are used
To prevent a shock hazard the 30 minute timer shall not be
installed inside the steam room.
EXTERNAL TERMINAL CONNECTIONS