![background image](http://html1.mh-extra.com/html/federal-signal-corporation/pagasys-gen-ii/pagasys-gen-ii_description-installation-and-user-manual_3810158028.webp)
28
GENII-RA700 Remote Amplifier
PAGASYS GEN II Remote Amplifier and Controller (GENII-RC and GENII-RA700)
Federal Signal
www.fedsig.com
4 4 2 Standby Wiring
Multiple Remote Amplifiers can be configured to have standby Remote Amplifiers to
support working amplifiers. The standby Remote Amplifier must be the highest-numbered
amplifier in the Networked Amplifier group (amplifiers 5 and 6 in the group below). All
Remote Amplifiers in the Networked Amplifier Group must be daisy-chained as indicated
in the following figure.
Figure 7 Standby Wiring
`
`
`
Amps #1 & #2
`
Amps #3 & #4
Amps #5 & #6
(Standby)
When configuring a standby Remote Amplifier in a Networked Amplifier Group, both
Remote Amplifiers in a standby chassis must be configured with a standby zone, and only
one standby chassis may be configured as a standby in a Networked Amplifier Group.