![Federal Signal Corporation PAGASYS GEN II Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/federal-signal-corporation/pagasys-gen-ii/pagasys-gen-ii_description-installation-and-user-manual_3810158023.webp)
23
GENII-RA700 Remote Amplifier
Description, Installation, and User Manual
Federal Signal
www.fedsig.com
4 2 2 Factory Reset Button
The factory reset button is used to erase all custom settings and revert the GENII-RA700
to GENII mode.
To perform a factory reset:
1. Press and hold the Factory Reset Button.
2. Power-cycle the GENII-RA700 (or power it on, if it was off).
3. Continue to hold the Factory Reset Button for 15 seconds.
4. Release the Factory Reset Button.
5. Power-cycle the GENII-RA700 again.
6. Done.
After a factory reset, the GENII-RA700’s IP settings will reset to default; see “4.4.1 Network
Configuration” on page 27. The Dante® settings will also revert to default, meaning
the Dante® will lose its static IP address, name, and any redefined channel labels. It will
be necessary to put the system on a network with a DHCP server so Dante® can request
an IP address. Then, via the Dante® Controller, assign a static IP address and make any
desired changes to the device name and its channel labels.