4 3 GENII-RA700 System Faults
There are a number of hardware faults the GENII-RA700 can report to its PAGASYS GEN II
controller.
4 3 1 Per Chassis
Each of the following represents a fault at the chassis level.
Table 18 Fault at the Chassis Level
Fault
Description
Resolution
Code CRC failed
The firmware has become
corrupted.
Replace unit.
Stack overflow
An error in the firmware has
corrupted the stack.
Reboot unit, report to Federal
Signal.
Assert
An unexpected error has
occurred in the firmware.
Reboot unit, report to Federal
Signal.
Config defaulted
The configuration memory has
become corrupted and has
reverted to factory defaults.
Replace unit.
Amplifier
should
continue to function in the interim
after reconfiguration.
Profile error
The manufacturing information
has become corrupted (serial
number, build date, etc.).
Replace unit.
Amplifier
should
continue to function in the interim.
PSU over-voltage
The power supply is
overvoltage.
Replace unit.
PSU under-voltage
The power supply is under
voltage.
Replace unit.
I
2
C bus failed
An internal serial bus has failed. Replace unit.
DSP boot failed
The firmware was unable to
boot the DSP.
Replace unit.
DSP link failed
The firmware cannot
communicate with the DSP.
Replace unit.
DSP watchdog failed The DSP has encountered a
watchdog timeout.
Replace unit.
Fan 1 failed
Chassis fan 1 has failed.
Replace unit.
Amplifier
should
continue to function in the interim,
provided fan 2 is still working.
Fan 2 failed
Chassis fan 2 has failed.
Replace unit.
Amplifier
should
continue to function in the interim,
provided fan 1 is still working.