![background image](http://html1.mh-extra.com/html/federal-signal-corporation/pagasys-gen-ii/pagasys-gen-ii_description-installation-and-user-manual_3810158012.webp)
12
GENII-RC Remote Controller
PAGASYS GEN II Remote Amplifier and Controller (GENII-RC and GENII-RA700)
Federal Signal
www.fedsig.com
3 2 2 Rear Panel
Figure 2 GENII-RC Rear Panel
Serial
console for
CPU/DSP
diagnostics
& recovery
Redundant
network
cable
(Dante
®
)
GENII
amplifier or
Aux audio
out
8 Access
panels
A/B
controller
link
AC power in
8 Digital
outputs
8 Digital
inputs
SD card for
file upload
Fault
relay
output
Expansion
bus for I/O
& beacon
cards
Table 5 GENII-RC Inputs and Outputs
Digital inputs (8)
• Dry-contact mode
• Max output voltage: 5.5 V (open circuit)
• Max output current: 5 mA (short circuit)
• Wet-contact mode
• Max input voltage: 30 V
• Min input voltage to activate: 5 V
• Input current: 5 mA at 24V
Programmable relay outputs (8)
• Configuration: SPDT (single-pole, double-throw)
• Rated current: 1 A
• Rated voltage: 48 Vdc
RJ45 Ethernet ports (2)
• Speed: 1 Gigabit
• Internal connection: Ethernet switch (acts as a
2-port switch)
• Dante
®
network audio: yes
RJ45 A/B link interface port (1)
• Used for interconnecting GENII-RCs in A/B
systems
• For pinout, see “Table 8 RJ45 Connections” on
RJ45 I/O interface port
Supports up to 63 daisy-chained GEN II I/O boards.
NOTE
: If power usage of the cards on the port
exceeds 0.5 A, a power injector I/O card is needed.
See the PAGASYS
®
GEN II manual 25500458 for
information on I/O card power usage.
RJ45 Amp interface port (1)
• Max amplifiers: 128 GEN II amplifiers
• Standby amp support: yes
• ISMT support: optional, requires ISMT cards