19
GENII-RA700 Remote Amplifier
Description, Installation, and User Manual
Federal Signal
www.fedsig.com
4 1 3 PAGASYS GEN II I/O Cards
Any combination of up to 63 PAGASYS GEN II I/O cards can be connected to provide
additional I/O, cabinet fan control and monitoring, and beacon control and monitoring.
The I/O cards are connected over the network to a PAGASYS GEN II controller and
function as if they are directly connected to the controller. Note that the count of 63
cards does not include any necessary power-injector cards. For specific configuration
information, see the PAGASYS GEN II SYSTEM MANAGER Software (Model P-SYSMGR-G)
manual document number 25500459.
4 1 4 System Robustness
GENII-RA700 amplifiers continually run self-checks to ensure that any fault is detected
and reported promptly. Speaker outputs are thermally and electrically monitored.
Supplemental GENII-RA700 amplifiers can act as dedicated standby amplifiers, taking
over the speaker outputs of amplifiers that have failed.
4 2 GENII-RA700 Specifications
Table 9 GENII-RA700 Environmental and Physical Specifications
Operating temperature range
14˚F to 131˚F (-10˚C to +55˚C)
Humidity range
0-95%, non-condensing
Dimensions (Height x Width x Length) 3.5 x 19.0 x 18.0 inches (88 x 483 x 456 mm)
Weight
17.0 lb (7.7 kg)
Table 10 GENII-RA700 Power Input, AC Model
Input voltage range
100-264 Vac
Frequency
50-60 Hz
Max current
8.7 A at 10 V
Max operating power 870 W
Table 11 GENII-RA700 Power Input, DC Model
Input voltage range
40-56 Vdc
Max current
823 A at 40 V
Max operating power 870 W
Table 12 Amplifier
Quiescent power
45 W (0.375 A) at 120 Vac
Rated output voltage
70 V
RMS
or 100 V
RMS
, depending on model
Max output power
350 W per channel
Frequency Response 200-15000 Hz
THD
<1%
Sensitivity
0.775 V
RMS
at 1 kHz