
6
Safety Messages
Informer100 Speaker (Models IS-I-IP100ACX and IS-I-IP100DCX)
Federal Signal
www.fedsig.com
• The nameplate should NOT be obscured, as it contains cautionary and/or other
information of importance to maintenance personnel.
• After installation and completion of the initial system test, provide a copy of
these instructions to all personnel responsible for operation, periodic testing, and
maintenance of the equipment.
• File these instructions in a safe place and refer to them when maintaining and/or
reinstalling the device.
• This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D; Class II,
Division 2, Groups F and G; Class III or nonhazardous locations only.
• Substitution of any components may impair suitability for Division 2.
EXPLOSION HAZARD: Do not disconnect the equipment unless power has been
switched off or unless the area is known to be non-hazardous.
EXPLOSION HAZARD: Do not remove or replace fuse when energized.
Failure to follow all safety precautions and instructions may result in property damage,
serious injury, or death.
Installation and Service
• After installation or service, test the system to confirm that it is operating properly.
Test the system regularly to confirm that it will be operational in an emergency.
• If future service and operating personnel do not have these instructions to refer to,
the system may not provide the intended audible warning, and service personnel
may be exposed to death, permanent hearing loss, or other bodily injury. File these
instructions in a safe place and refer to them periodically. Give a copy of these
instructions to new recruits and trainees. Also give a copy to anyone who is going to
service or repair the Informer100 Speaker.
• To reduce the risk of electric shock, do not perform any servicing other than what
is contained in the operating instructions unless you are qualified to do so. Refer all
servicing to qualified service personnel. Always test the Informer100 Speaker before
using after repairs have been made.
Ethernet Wiring
• Unless shielded or run in conduit, Ethernet wiring must be at least six feet from bare
power wiring or lightning rods and associated wires, and at least six inches from
other wire (for example, antenna wires, doorbell wires, wires from transformers to
neon signs), steam or hot water pipes, and heating ducts.
• Do not place Ethernet wiring or connections in any conduit, outlet or junction box
containing high voltage electrical wiring.
• If using a cable gland, gland must be Listed. The Informer100 Speaker has 3/4-inch
and 1/2-inch NPT entry sizes.