Pump Assembly Continued
Figure 63 - Aligning Pump Shaft Keyway
6.
Rotate both shafts until the pump shaft
key and the flexible coupling keyway are
aligned.
APPLY SYSTEM COMPLIANT
ANTI-SEIZE COMPOUND
Figure 62 - Pump Shaft Key Installation
5. Apply system compliant anti-seize com-
pound in the pump shaft keyway and install
pump shaft key
NOTES:
The rounded end of the pump shaft
key must be placed in the rounded end of the
keyway.
Figure 61 -
Flexible Coupling Set Screw
Location
4.
Install the flexible couple set screws and
tighten to torque specs specified in the
Fas-
tener Torque Specifications
section of this
manual.
NOTES:
Set screws are only on the motor side
of the flexible coupling. No set screws should
be installed on the pump shaft side of the cou
-
pling.