2. Apply system compliant anti-seize com-
pound on the motor shaft and in the motor
shaft keyway and install the motor shaft
key.
3.
Slide the flexible coupling over the motor
shaft with the motor shaft key.
NOTES:
If the motor shaft key does not fit
properly in the coupling keyway, lightly file the
motor shaft key until a proper fit is obtained.
Figure 37 -
Install Flex Coupling On Motor
Shaft
Pump Assembly Continued
Figure 36 - Direction Arrows On Motor Adapter
Vertical Motor Installation
1. Prior to pump installation energize the motor
to determine the direction of motor rotation.
The correct rotation is indicated by arrows
on the motor adapter. If the rotation is incor-
rect, reverse the polarity of motor wiring to
change the direction of rotation.
NOTES:
Reversing polarity of the VFD power
input wires will not change the motor rotational
direction.
NOTES:
If the motor rotational direction is cor-
rect, disconnect power to the motor according
to lock-out/tag-out procedures and complete all
electrical connections according to local codes
and regulations.
APPLY SYSTEM COMPLIANT
ANTI-SEIZE COMPOUND