![FE FSH Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/fe/fsh/fsh_instruction-manual_3753975041.webp)
INF-TN1FSH-E
- 33 -
(5) Apply silicon rubber evenly over the entire
ultrasonic transmission surface and the contact
surface of the temperature sensor piping, being
careful not to let air bubbles mix in.
(6) Clean the surface of the piping, and then mount the
sensor unit.
Separate the wire rope apart from each other, place
the sensor unit closely contacted to the piping, and
engage the wire rope in the grooves at the front and
the rear of the sensor.
(7) Align the match mark of the sensor unit and the
marking line.
The absorber unit is not required for resin piping.
Proceed to (11) in this case.
The absorber unit is used for metal piping. Proceed
to (8) in this case.
(8) Apply silicon rubber evenly over the entire
installation surface of the absorber unit.
(9) Clean the surface of the piping, and then mount the
absorber unit.
Separate the wire rope apart from each other, place
the absorber unit closely contacted to the piping so
that it contacts the front face of the sensor unit, and
then lay the wire rope..
Groove
Groove
Marking line
Marking line
Matching mark
Matching mark
Position the sensor
by making the
guides on the
absorber unit side
sandwich the
sensor.