4th edition, 9-11-2018
7000.05050, 4th edition, 9-11-2018
7000.05050
Parameter description
44
Manufacturer’s Hardware Version
The segmented SDO record must be read to determine the manufacturer’s hardware ver-
sion.
Manufacturer’s Software Version
The segmented SDO record must be read to determine the manufacturer’s software ver-
sion.
Guard Time
The guard time is stated in milliseconds. The value 0 switches node guarding off
(chap. 3.8.2.1, p. 30).
Life Time Factor
The life-time factor multiplied by the guard time gives the life-time for the node guarding
(chap. 3.8, p. 27). The value 0 switches node guarding off.
Store Parameters
Tab. 21: Saving parameters
The “Save Parameters” object saves the configuration parameters into the flash memory.
Read access supplies information about the save options. Writing the “Save” signature to
the respective subindex initiates the save procedure.
Index
Subindex Name
Type
Attr.
Default value
Meaning
0x1009 0x00
Manufacturer’s
Hardware Version
Vis
string
const
–
Hardware version
Index
Subindex Name
Type
Attr.
Default value
Meaning
0x100A 0x00
Manufacturer’s
Software Version
Vis
string
const
–
Software version
Index
Subindex Name
Type Attr.
Default value
Meaning
0x100C 0x00
Guard Time
U16
rw
0
Monitoring time for node guarding
Index
Subindex Name
Type Attr.
Default value
Meaning
0x100D 0x00
Life Time Factor
U8
rw
0
Time factor for node guarding
Index
Subindex Name
Type Attr.
Default value
Meaning
0x1010 0x00
Number of entries
U8
ro
9
Number of object entries
0x01
Save All Parameters U32
rw
1
Saves all parameters
0x02
Save comm param-
eters
U32
rw
1
Save the communication parameters
(object directory entries 0x0000 to
0x1FFF)
0x03
Save app parame-
ters
U32
rw
1
Save the application parameters (object
dictionary entries 0x2000 to 0x6FFF)
0x04
Save app
parameters 1
U32
rw
1
Save application parameters for direct
changes (set 1)
0x05
Save app
parameters 2
U32
rw
1
Save application parameters for direct
changes (set 2)