4th edition, 9-11-2018
7000.05050, 4th edition, 9-11-2018
7000.05050
Overview
12
Pre-controls
General settings
These parameters are stored twice. In operation the system can switch quickly between
these different pre-set values.
Index
Subindex Name
Type
Attr.
Meaning
0x2349
0x01
Torque/force feed forward factor U8
rw
Factor for the torque or force control
0: 0% activation of the pre-control value
128: 100% pre-control
0x02
Torque/Force feed forward delay U8
rw
Setpoint delay:
0: undelayed activation
1: Activation delayed by one sampling
0x234A
0x01
Velocity feed forward factor
U8
rw
Factor for the torque or force control
0: 0% pre-control
128: 100% pre-control
0x02
Velocity feed forward delay
U8
rw
Setpoint delay:
0: undelayed activation
1: Activation delayed by one sampling
Index
Subindex Name
Type
Attr.
Meaning
0x6060
0x00
Modes of operation
S8
rw
Select the operating mode
–4: ATC
–3: AVC
–2: APC
–1: Voltage Mode
0: Controller not activated
1: PP
3: PV
6: Homing
8: CSP
9: CSV
10: CST
0x6081
0x00
Profile Velocity
U32
rw
Profile velocity [in user-defined scaling]
0x6083
0x00
Profile acceleration
U32
rw
Profile acceleration [1/s
2
]
0x6084
0x00
Profile deceleration
U32
rw
Profile deceleration [1/s
2
]
0x6086
0x00
Motion Profile Type
S16
rw
Motion profile type:
0: Linear profile
1: Sin
2
velocity
0x60E0
0x00
Positive torque limit value
U16
rw
Value of the upper limit value [in relative
scaling]
0x60E1
0x00
Negative torque limit value
U16
rw
Value of the lower limit value [in relative
scaling]