4th edition, 9-11-2018
7000.05050, 4th edition, 9-11-2018
7000.05050
CANopen protocol description
34
3.10.2
Equipment faults
Tab. 12: FAULHABER error register (0x2320)
The FAULHABER error register contains the most recent errors in bit-coded form. The errors
can be masked by selection of the desired types of error via the error mask object (0x2321).
Tab. 13: Error coding
All of these errors correspond to the emergency error code (see chap. 3.6, p. 24).
The error mask describes the handling of internal errors depending on the error coding (see
Tab. 13).
Index
Subindex Name
Type Attr.
Default value
Meaning
0x2320 0x00
Fault Register
U16
ro
–
FAULHABER error register
Error bit Error message
Description
0x0001
SpeedDeviationError Speed deviation too great
0x0002
FollowingError
Following error
0x0004
OverVoltageError
Overvoltage detected
0x0008
UnderVoltageError
Undervoltage detected
0x0010
TempWarning
Temperature exceeds that at which a warning is output
0x0020
TempError
Temperature exceeds that at which an error message is output
0x0040
EncoderError
Error detected at the encoder
0x0080
IntHW error
Internal hardware error
0x0100
ModuleError
Error at the external module
0x0200
CurrentMeasError
Current measurement error
0x0400
Memory error
Memory error (EEPROM)
0x0800
ComError
Communication errors
0x1000
Calculation error
Internal software error
0x2000
DynamicError
The current velocity is higher than the maximum speed set for the motor.
0x4000
–
Not used, value = 0
0x8000
–
Not used, value = 0