4-13
1
2
3
4
Ethernet Communication
Setting/Reading Individual Sensor Descriptions
4-5 Setting/Reading Individual Sensor
Descriptions
CDX Series products allow for writing and reading of individual descriptions.
Descriptions are limited to 30 bytes of characters.
Read
Sent command
30
06
00
00
01
60
00
1E
Reply command
B4
00
Individual sensor description (30 bytes)
Writing
Sent command
40
02
01
60
00
1E
Write data (30 bytes)
Reply command
C0
00