eb Settings Screen and Function Details
Checking the IP Address on CDX Series Products
Once the software is launched, a search for all CDX Series products on the network will begin automatically.
4
5
6
7
8
1
2
3
Number
Item
Description
1
Broadcast display
:KHQRSHUDWLRQLVEHLQJFDUULHGRXWFRUUHFWO\³%&$67´ZLOOÀDVK
2
Product
Displays the CDX Series product model.
3
Version
'LVSOD\VWKH&';6HULHV¿UPZDUHYHUVLRQ
4
Mac address
Displays the Mac address of the CDX Series product.
5
IP address
Displays the IP address of the CDX Series product. Press “Setting” to display the
menu for changing network settings.
6
Description
Use this function to provide any additional notes. Double-click to edit.
7
Measured value
The current measurement results will be displayed.
8
Easy arithmetic
monitor
You can add/subtract the measured values of multiple sensors. Select the sensors
from the lists, and then click the “+” or “-” mark to switch the type of calculation.
Opening the CDX Settings screen
To view the settings and actions of a CDX Series product, click the “WEB” button for the in the list to display
the measurement screen for that CDX Series product.
Changing the IP address
Press the “Setting” button from the menu to bring up the IP address update menu for the sensor.
Change the address and press “OK” to change the communication settings immediately.
There is no need to restart the CDX Series product.