![Fastus CDX Series Скачать руководство пользователя страница 71](http://html2.mh-extra.com/html/fastus/cdx-series/cdx-series_user-manual_4594473071.webp)
4-11
1
2
3
4
Ethernet Communication
Acquiring Measured Values with Time Data
4-3 Acquiring Measured Values with
Time Data
When measuring thickness, controlling feedback, or performing similar operations, the measurement results
of the CDX Series are used when highly accurate time is necessary.
When this command is used, the CDX Series attaches the timestamp to the measured value and then
outputs the value.
Sent command
30
06
00
00
01
F0
00
0C
Reply command
B0
0C
Measurement value
(4 bytes)
Sensor status/measurement result
(4 bytes)
Timestamp
(4 bytes)
The sensor status and measurement formats are the same as “4-2-1 Acquiring measured results”(Page
4-4).
A value between 0 and 999999999 (nsec) is used as the timestamp, which counts down one second at a
time to 0. Checking this value allows the user to understand the measurement timing and order of
measurement data acquired through communication.