Entering remaining data into your Raven console.
The
sequence
for entering data into the remaining keys are as
follows: 1. press key you wish to program. 2. press enter. 3. enter
proper number (s). 4. press enter key again.
Your
information is now locked in.
BOOM CAL
numbers, programming boom sections. All sections
must be programmed. Use 0 in sections you do not use.
Press BOOM CAL key to access boom sections and use arrow keys
to scroll to different boom sections.
Enter numbers from Raven calibration card.
SPEED CAL
number, start with one of the following #'s or
consult the Raven manual for more options. All speed cal #'s
must be verified
by zeroing the distance key and driving a
premeasured distance.
Sky Tracker 598, Raven Radar 598, proximity sensor 930.
Magnetic wheel sensor with four magnets:
2100
for 320/90R46,
2180
for 380/90R46.
Raven ENVIZO 785
METER CAL
number, this number is located at the Raven
flowmeter and is stamped on a white tag attached to the
flowmeter cable.
The flowmeter is normally mounted on the rear boom frame or on
the new Fast Model's under the main tank. The number is usually
between 700 and 720.
VALVE CAL
number
The number Fast & Raven recommend to use is 2123.
This number regulates the motorized control valve operation.
RATE 1
Enter your target rate in gallons per acre. Note, the Raven console
puts one decimal point in this number so you may have to add an
addition 0.
RATE 2
If
you do not use a second rate enter the same rate as
in RATE 1.
Enter a second target rate in gallons per acre. Note, the Raven
console puts one decimal point in this numberso you may have to
add an additional 0.
CAL
should stop flashing in left side display.
If CAL is still flashing you have missed programming one or more
of the 3 through 8 functions. Press each key to verify.
VOL/TANK,
counts down the number of gallons being sprayed
out of the main supply tank
.
Enter the number of gals. in main supply tank. Each time the tank
is filled the total # of gals. left in the tank must be entered.
TIME
Enter in military time.
After you have programmed these first three functions they are locked in. To scroll through your selections hold the self-test key. If
you wish to change these selections turn the power ON/OFF switch to off. Then while holding the CE key turn the ON/Off switch to
on. This will reset and clear information from the entire console. If you wish to only change information in any of the first three
selections press and hold the self-test key for 30 seconds. The display will start to flash and you can reprogram as outlined above
without losing information in the rest of the console.
The bottom row of keys are for information and do not need to be programmed. Acre, volume and distance counters can be
zeroed out by selecting it's function/information key and entering 0.
Boom width calibration for broadcast applications.
Refer to the Raven manual for band spraying applications. US boom sections
are always calibrated in inches. On broadcast applications always take the number of nozzle outlets in each section times (x) their
spacing. Example, for 12 outlets spaced at 20" you would enter 240. At this time you should physically check your outlet spacing,
number of sections and the number of outlets in each section. Record your boom widths on the Raven calibration card. Fence line
outlets are not normally counted. Verify that your total boom section inches match your total boom width.
6/29/2012
2
Содержание 973P Series
Страница 1: ...1 HIGH CLEARANCE CENTER PIVOT SUSPENDED BOOM 3 PT FIELD SPRAYER 973P SERIES OPERATOR S MANUAL...
Страница 45: ...45 Fig 62 BOOM TILT PIVOT 3 Grease boom tilt pivot 1 location each boom Left Right...
Страница 59: ...59 7 4 ELECTRICAL SCHEMATIC OPTIONAL CABLE 10 CONSOLE 3 OR 6 BOOM SCS 440 450 CONSOLES...
Страница 60: ...60 7 5 OPTIONAL CABLE FLOW CONTROLLER UP TO 6 BOOM VALVES...
Страница 61: ...61 7 6 5 FUNCTION HYDRAULIC BLOCK PARTS Note for open center systems only install plug 10 for closed center...
Страница 62: ...62 7 7 5 FUNCTION HYDRAULIC CAB BOX...
Страница 63: ...63 7 8 5 FUNCTION HYDRAULIC CAB BOX SWITCH WIRING...
Страница 67: ...67...