Fan Control
EZ-EFI
®
has two electric fan outputs with independently adjustable Fan On Temperatures. Select the
desired fan and adjust the activation point with the dial on the right hand side of the screen. Rotate the
dial clockwise to raise the activation point and counter clockwise to lower the activation point.
Fan Off Temperature is automatically adjusted up or down along with the Fan On Temperature.
When coolant temperature goes above a Fan On Temperature setting, that fan output becomes active
and its output wire goes to ground to trigger a fan relay. (Fan 1 uses the blue “FAN 1 RELAY” wire.
Fan 2 uses the blue/white ‘FAN 2 RELAY” wire.) When coolant temperature drops below that fan’s
Fan Off Temperature setting, the output is disabled.