42
Chapter 1: Introduction to the FaroArm
®
• Disable the R
ANGE
F
INDER
dialog box by clearing the Range Finder
On/Off check box.
• Select the S
HOW
V
ISIBLE
L
IGHT
check box to add all visible light to
the Preview window.
N
OTE
: Adding all visible light to the preview window will decrease
the number of frames per second sent to the computer and should only
be used when diagnosing problems with the FARO Laser Line Probe.
• Select the H
IGH
A
CCURACY
M
ODE
check box to operate the Laser
Line Probe in the High Accuracy mode. High Accuracy mode can
improve the performance of the Laser line probe by up to 30%, but
reduces your field of view by 1/2 and shortens your effective
maximum scanline width to 2/3 of the normal width.
Scan Rate and Density
Use the Scan Rate Density settings for data reduction. Reducing the
number of points the Laser Line Probe collects can improve system
performance, increase scanning speed and potentially reduce unwanted
noisy data.
• Scan Rate - choose the number of scan lines per second. 1/1 is the
normal rate of scan lines per second, set this to discard scan lines.
N
OTE
: Always set the scan rate to 1/1 when calibrating the Laser Line
Probe.
• Scan Density - choose the number of points on each scan line. 1/1 is
all of the points on the laser line, set this to discard points on each
line.
• Information - displays the unique information for the current FARO
Laser Line Probe.
Basic Settings
• From the M
ATERIAL
drop-down window choose any existing material
setting. Use the commands in this drop-down window to save
material settings.
N
OTE
: The current material setting is stored on your computer and in
the FaroArm. If you connect the FaroArm to another computer, the
current material will be
Unknown
. Save the material settings to copy
the settings from the FaroArm to the new computer.
• Click the AUTO button to set the Exposure and Noise Threshold
levels for the current material. Hold the Laser Line Probe in position,
08M46E00_FaroArmUSB.book Page 42 Tuesday, February 17, 2009 1:42 PM
Содержание FaroArm Fusion
Страница 2: ...08M46E00_FaroArmUSB book Page 2 Tuesday February 17 2009 1 42 PM ...
Страница 4: ...08M46E00_FaroArmUSB book Page 4 Tuesday February 17 2009 1 42 PM ...
Страница 8: ...08M46E00_FaroArmUSB book Page iv Tuesday February 17 2009 1 42 PM ...
Страница 100: ...08M46E00_FaroArmUSB book Page 92 Tuesday February 17 2009 1 42 PM ...
Страница 113: ...B 9 08M46E00_FaroArmUSB book Page 9 Tuesday February 17 2009 1 42 PM ...
Страница 114: ...08M46E00_FaroArmUSB book Page 10 Tuesday February 17 2009 1 42 PM ...
Страница 120: ...08M46E00_FaroArmUSB book Page 6 Tuesday February 17 2009 1 42 PM ...
Страница 129: ...08M46E00_FaroArmUSB book Page 1 Tuesday February 17 2009 1 42 PM ...