28
28
111628W
Revision date: 09.25.18
3
ASSEMBLE THE DRAIN MANIFOLD
Required parts:
• 111560 2" PVC Pipe, WF6717 Slip Caps, and WF1386
Tee Fittings
• 111907 Conduit Hangers
• 113372 PVC Primer & WF6990 PVC Cement
Assembly Instructions
Complete these steps:
1. Using the 111560 2" pvc pipe, cut six (6) pieces at 8-3/4".
2. Take the WF1386 tee fittings and 8-3/4" tubes and assemble the center
stack of the drain manifold as shown.
Use pvc primer and cement to
attach the vertical 8-3/4" tubes to the tee fittings.
Assemble on a flat
surface for best results and to keep the tee fittings aligned. Verify that the
tubes are seated in each tee fitting before the cement sets.
3. As the cement sets for the center stack, take the bulk 2" pvc tubing and
cut seven (7) sections at 23" each.
8-3/4"
WF1386
Tee Fitting
WF1386
Tee Fitting
DRAIN MANIFOLD –
CENTER STACK
Length of
each tube:
8-3/4".
NOTE:
Cement all 8-3/4"
pvc sections to the
WF1386 tee fittings.
23"
4. Clean all debris from inside the tubes and remove any loose material from
the ends of each tube.