33
Revision date: 09.25.18
111628W
ASSEMBLE THE DRAIN MANIFOLD — continued
Assembly Instructions
3
18. Take the tube back to the fodder frame and drain stack and insert it into the fitting to check fit and hole alignment. Set the drain elbows of the two channels
into the holes to check the fit.
NOTE:
To verify that the tube will work at other levels, check a couple different positions. If the tube works at other locations, use it as a template and
create the remaining horizontal drain tubes. If drilled correctly, tube should work at all levels.
19. After creating all horizontal tubes, attach tubes to the drain manifold stack.
Coat outside of tube end and inside of fitting with pvc primer and cement
and insert end into open socket of tee fitting.
NOTE:
Verify that drain holes of each tube are pointing up and are aligned
with the channel drain elbows. Slide channels back and away from the drain
manifold tubes until the pvc cement has dried.
Adjust tubes as needed
before the pvc cement sets up.
Gently lift open
end of tube to create a slight slope toward drain stack. This helps water
drain from horizontal tubes.
Step 18: Check fit. Also check
fit at other levels before drilling
remaining tubes.
Slightly lift the end of each
tube during installation
before the cement sets
so
tubes slope toward vertical
drain stack.