1.  Use this unit in the manner intended by the manufacturer. If you have 

any questions, please contact the manufacturer .

2.  Before servicing or cleaning unit, switch power off at service panel 

and lock the service disconnecting means to prevent power from 
being switched on accidentally. When the service disconnecting 
means cannot be locked, securely fasten a prominent warning 
device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 
including fire-rated construction.

4.  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to pre-
vent back drafting. Follow the heating equipment manufacturer’s 
guideline and safety standards such as those published by the 
National Fire Protection Association (NFPA), and the American 
Society for Heating, Refrigeration and Air Conditioning Engineers 
(ASHRAE), and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  If this unit is to be installed over a tub or shower, it must be marked 

as appropriate for the application and be connected to a GFCI 
(Ground Fault Circuit Interrupter) – protected branch circuit.

8.  NEVER place a switch where it can be reached from a tub or shower.
9.  This fan must be properly grounded.
10.  Do not use in the cooking area (Figure. 1).

Floor

Cooking 

Equipment

Cooking area

Do not install above 

or inside this area

45

45

Figure 1

11.  Do not block the air intakes or exhaust.
12.  Power supply wiring is to be No. 14 AWG wire or larger (suitable 

for at least 90°C (190°F) ).

13.  Not for use outdoors.
14.  For lighted units, use only CFL type T4, 26W lamp and a maxi-

mum 4 W night light .

15.  The fan must not be installed in a ceiling with an “R” rating 

greater than 40.

16.  The fan is type IC (Inherently Protected).
17.  To reduce the risk of injury, install the fan at least 7 feet (2.1m) 

above the floor.

18.  Acceptable for use over a shower or tub when installed in a GFCI 

protected branch circuit.

19.  The fan should not be turned on or off rapidly.
20.  Do not clean the fan with corrosive chemicals or water in excess of 

60° C (140° F).

21.  If the fan is not operating properly, shut the power off immediately, 

and have a certified installer inspect it and have it serviced as 
required.

22.  These fan must be mounted to structural members that are strong 

enough to support the fan’s weight.

23.  Do not allow foreign objects to enter the fan; this could result in 

electric shock or fan damage.

READ AND SAVE THESE INSTRUCTIONS!

Read carefully all instructions before installing or using this product 

FQ Series Fan

FQ Series Fan-Lights

Package Includes:

1  Fantech Exhaust Fan or Fan-Light
5  Mounting Brackets
8  Mounting screws
1  26W CFL Type T4 (Fan-Light models only)
1  4w night light (Fan-Light Models only)

WARNINGS:

  BEFORE INSTALLATION, TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

CAUTION

:  

1.  For general ventilating use only. Do not use to exhaust haz-

ardous or explosive materials and vapors.

2.  This product is designed for installation in flat ceilings only. 

Do not install it in a sloping ceiling or in a wall.

3.  To avoid motor bearing damage and noisy unbalanced impel-

lers keep construction material / dust from entering the fan.

4.  Please read specification label on the product for further 

information and requirements.

Содержание FQ80

Страница 1: ...r intakes or exhaust 12 Power supply wiring is to be No 14 AWG wire or larger suitable for at least 90 C 190 F 13 Not for use outdoors 14 For lighted units use only CFL type T4 26W lamp and a maxi mum...

Страница 2: ...the keyhole on each bracket on the joists NOTE The bottom edge of the housing should be flush with the bottom of the joist Figure 4 4 Remove the housing and drive the screws part way into the joists...

Страница 3: ...to the housing To clean the impeller and housing remove the motor and then wash with water or a neutral detergent as required NOTE Keep all electrical components away from water Do not use corrosive...

Страница 4: ...8 Industrial Blvd Lenexa KS 66215 Phone 800 747 1762 913 752 6000 Fax 800 487 9915 913 752 6466 www fantech net info fantech net Canada 50 Kanalflakt Way Bouctouche NB E4S 3M5 Phone 800 565 3548 506 7...

Страница 5: ...pour au moins 90 C 190 F 13 Ne doit pas tre utilis l ext rieur 14 Pour les unit s clairage utiliser uniquement des lampes fluorocompactes de type T4 de 26 W et une veilleuse de 4 W maximum 15 Le venti...

Страница 6: ...MARQUE Le bord inf rieur du bo tier doit affleurer le bord inf rieur de la solive Figure 4 4 Retirer le bo tier et enfoncer les vis mi course dans les solives aux endroits marqu s Figure 5 vercle du b...

Страница 7: ...e laver au besoin avec de l eau ou un d tergent neutre REMARQUE loigner tous les composants lectriques de l eau Ne pas utiliser de produits chimiques corrosifs ou d eau une temp rature sup rieure 60 C...

Страница 8: ...Industrial Blvd Lenexa KS 66215 T l phone 800 747 1762 913 752 6000 T l copieur 800 487 9915 913 752 6466 www fantech net info fantech net Canada 50 Kanalflakt Way Bouctouche NB E4S 3M5 T l phone 800...

Страница 9: ...mentaci n deben realizarse con cables calibre 14 AWG o m s gruesos aptos para al menos 90 C 13 No apto para uso externo 14 En las unidades con luces utilice nicamente una l mpara CFL tipo T4 de 26 W y...

Страница 10: ...aci n de cada m nsula en las viguetas NOTA El borde inferior de la carcasa debe estar al ras de la parte inferior de la vigueta Figura 4 4 Retire la carcasa e introduzca parcialmente los tornillos en...

Страница 11: ...a extraiga el motor y luego l velas con agua o con un detergente neutro seg n sea necesario NOTA Mantenga todos los componentes el ctricos lejos del agua No utilice productos qu micos corrosivos ni ag...

Страница 12: ...215 Tel fono 800 747 1762 913 752 6000 Fax 800 487 9915 913 752 6466 www fantech net info fantech net Canad 50 Kanalflakt Way Bouctouche NB E4S 3M5 Tel fono 800 565 3548 506 743 9500 Fax 877 747 8116...