12
Fancom 771
INSTALLER: 5. Installer settings
21
Select option 1-1: Relay assignments. The following will appear on the display:
The relay assignments apply to the kitchen controls. The IRMs on address 1 and 2 are reserved for this
purpose (see appendix 1). The value 1000 is added to the relay number. This indicates that the IRM.16
relays concerned can be entered directly. This is contrary to the IRMs for the valves, which can also have
matrix or K.64 control.
1001 means relay 1 on IRM.16 address 1
1016 means relay 16 on IRM.16 address 1
1017 means relay 1 on IRM.16 address 2
The values 1001 thru 1032, respectively 1 thru 32, may only be entered for the kitchen control. If direct
control is also used for the valve controls, start with the first free relay and then number up to 1480 (see
section 5.1.3 Installation valve ).
We do not recommend changing the factory settings of the settings above. After the correct assignment
has been entered, this can be tested directly by setting the software switch to ON ( - key).
This test can be stopped by setting this switch to OFF ( - key). To indicate that the I/O test has been
started, the indication light in the alarm key will flash and the warning I/O-test started will be
displayed at this alarm key. After all relays have been assigned and tested, the alarm can be reset in the
usual way.
Ensure that all software switches are reset to OFF!
Two settings per ingredient are reserved for low and high speed. Usually these settings are set to the
same value to prevent errors,single speed motors should then be used.
5.1.1 INSTALLATION option 1-1 Relay assignments
☞
21
3x
>>Relay assignments
Alarm
1001
Outlet
1002
OFF
Mixer
1003
OFF
Auger dose out
1004
OFF
Circuit_1
1005
OFF
Feed bin low_1
1008
OFF
Feed bin high_1
1009
OFF
Time clock_1
0
Block dos.in
0
OFF
Bridge breaker
0
OFF
Feeder test
0
OFF
Valve protect.
0
OFF
Process active
0