30
This window shows you a lot of different information and gives possibilities to
test the currently used hardware and settings but also can be used for manual
calibration:
On the upper left side there is a checkbox named ‘Enable auto calibration mode’
as shown on the right hand side
(Note: This checkbox is shown on driver
page ‘settings’ if CSL Elite Pedals LC are
connected to wheel base):
This checkbox is deactivated per default when auto calibration mode is active
or after updating the CSL Elite Pedals LC firmware. Activate this checkbox
manually to enable the manual calibration mode (indicated in driver window:
The buttons right above and below each pedal indicator bar are displayed only
when manual calibration mode is active after a moment). See chapter ‘Pedal
manual calibration’ of this manual for more details about the calibration process
itself.
On the lower left side you can see the indi-
cator bars for each single pedal and for the
ClubSport Handbrake, see picture on right
hand side:
When pressing a pedal of the CSL Elite Ped-
als the corresponding bar shows the signal
level as a blue indicator, depending on the
mechanical travel and on the manually cal-
ibrated minimum and maximum positions.
Same with the ClubSport Handbrake if con-
nected to the CSL Elite Pedals LC.
Above every single indicator bar there are buttons ‘set max’, below every single
indicator bar there are buttons ‘set min’. These buttons are only available when
checkbox ‘Enable manual mode’ was activated by user before to enter manual
calibration mode:
•
When pressing a ‘set max’ button the current mechanical position of the
corresponding pedal or the handbrake will be stored as the maximum
position for this pedal or handbrake axis.
•
When pressing a ‘set min’ button the current mechanical position of the
corresponding pedal or the handbrake will be stored as the minimum
position for this pedal or handbrake axis.
•
See more detailed description in chapter ‘Pedal manual calibration’ of this
manual.