IMPORTANT INFORMATION
ELECTRICAL SAFETY AND ADVICE REGARDING SUPPLEMENTARY ELECTRICAL PROTECTION
Commercial kitchens and foodservice areas are environments where electrical appliances may be located
close to liquids, or operate in and around damp conditions or where restricted movement for installation and
service is evident.
The installation and periodic inspection of the appliance should only be undertaken by a qualified, skilled
and competent electrician; and connected to the correct power supply suitable for the load as stipulated by
the appliance data label.
The electrical installation and connections should meet the necessary requirements to the local electrical
wiring regulations and any electrical safety guidelines.
We recommend:-
•
Supplementary electrical protection with the use of a type A residual current device (RCD)
•
Fixed wiring appliances incorporate a locally situated switch disconnector to connect to, which is easily
accessible for switching off and safe isolation purposes. The switch disconnector must meet the
specification requirements of IEC 60947.
Your attention is drawn to:-
BS 7671:2018
–Guidance Note 8 - 8.13 : Other locations of increased risk
It is recognized that there may be locations of increased risk of electric shock other than those specifically
addressed in Part 7 of BS 7671. Examples of such locations could include laundries where there are
washing and drying machines in close proximity and water is present, and commercial kitchens with
stainless steel units, where once again, water is present.
Where because of the perception of additional risks being likely, the installation designer decides that an
installation or location warrants further protective measures, the options available include:
•
Automatic Disconnection of Supply (ADS) by means of a residual current device having a residual
operating current not exceeding 30mA;
•
Supplementary protective equipotential bonding; and
•
Reduction of maximum fault clearance time.
The provision of RCDs and supplementary bonding must be specified by the host organization’s appointed
installation designer or electrical contractor and installed by a suitably qualified and competent electrician
so as to comply with Regulations 419.2 and 544.2
Содержание E3840
Страница 20: ...16 5 0 CRITICAL DIMENSIONS Figure 7 Critical dimensions...
Страница 30: ...11 0 WIRING DIAGRAMS 11 1 E3840 Wiring diagram 25...
Страница 31: ...26 11 2 E3840 Circuit diagram...
Страница 32: ...27 11 3 E3840X Wiring diagram...
Страница 33: ...27 11 4 E3840X Circuit diagram...
Страница 34: ...27 11 5 E3840F Wiring diagram...
Страница 35: ...27 11 6 E3840F Circuit diagram...
Страница 36: ...27 11 7 E3840FX Wiring diagram...
Страница 37: ...27 11 8 E3840FX Circuit diagram...