6
1.2.2 Clearances
The unit requires a clearance of at least 100mm to the rear between unit and any combustible wall.
A minimum vertical clearance of 750mm should be allowed between top edge of flue outlet and
any overlying combustible surface.
Important
If fryer is to be installed with other appliances then the instructions for every
model should be consulted to determine the necessary clearance to any wall
or overlying surface.
Some appliances require greater clearance distances than others. The largest
clearance will therefore determine overall distance for a complete suite of
adjoining appliances.
1.3
VENTILATION
The appliance ventilation requirements should be in line with national and local regulations.
For multiple installations, requirements should be added together. Installations should be made
in accordance with local and/or national regulations applying at the time.
A competent engineer must be used for any installation work.
1.4
ELECTRICAL SUPPLY
The unit is supplied with a 2 metre 5-core cord for connection to a 400V 3N~ supply
incorporating a suitable isolating switch.
In the event of the cable being replaced, a cable conforming to code designation 0245 IEC
57 (e.g. H07RH-F5G4) must be used for connection to a 400V 3N~ supply incorporating a
suitable isolating switch.
Check that no damage has occurred to the appliance and power cable during transit. If damage
has occurred do not use the appliance.
Ensure that the mains power cable is routed free from the appliance to avoid damage.
We recommend supplementary electrical protection with the use of a residual current device
(RCD). Periodical testing, repair and fixing wiring connection should only be undertaken by a
skilled and competent electrician.
This appliance is also provided with a terminal for connection of an external
equipotential conductor. This terminal is in effective electrical contact with all fixed
exposed metal parts of the appliance, and shall allow the connection of a
conductor having a normal cross-sectional area of up to 10mm². It is located on the
rear panel and is identified by the following symbol and must only be used for
bonding purposes.
Phase
Rated Current
L1
29A
L2
29A
L3
29A
Содержание E3840
Страница 20: ...16 5 0 CRITICAL DIMENSIONS Figure 7 Critical dimensions...
Страница 30: ...11 0 WIRING DIAGRAMS 11 1 E3840 Wiring diagram 25...
Страница 31: ...26 11 2 E3840 Circuit diagram...
Страница 32: ...27 11 3 E3840X Wiring diagram...
Страница 33: ...27 11 4 E3840X Circuit diagram...
Страница 34: ...27 11 5 E3840F Wiring diagram...
Страница 35: ...27 11 6 E3840F Circuit diagram...
Страница 36: ...27 11 7 E3840FX Wiring diagram...
Страница 37: ...27 11 8 E3840FX Circuit diagram...