Gas and Electrical Isolation Points
S.5.15
Ensure any separate gas shut off switches and electric switches provided for
cooking equipment and/or extractor fans are accessible and clearly labelled.
Care and Maintenance of Thermal and Operational Safety Devices
S.5.16
Your fryer is fitted with a thermal safety device. This will stop heating of medium if
it becomes overheated. This appliance will always fail safe so long as there is no
damage to the thermal safety device.
S.5.17
Failure to clean and check the safety and operational thermostats can impact the
performance of the appliance and increase the risk of an appliance fire.
S.5.18
Damage to the thermostat sensors or their capillaries can increase the risk of
overheating or fire.
S.5.19
Do not operate the fryer if the safety devices located within the fryer pan appear
to be dislodged or damaged.
S.6 MAINTENANCE SAFETY
S.6.1
Unless otherwise stated, parts which have been protected by the manufacturer
must not be adjusted by the installer or end user.
S.6.2
We recommend that the oil level sensor (Patent No.GB2002725.6 & PCT/
GB2020/050462) in X or FX models should be serviced annually.
S.6.3
Before any cleaning is undertaken, isolate appliance from mains power supply at
isolator switch.
S.6.4
Suitable protective clothing must be worn when cleaning this appliance.
S.6.5
If filtration is fitted, never pump water through the filtration pump at any time! Wa
-
ter and hot oil are an explosive mixture.
S.6.6
Oil must be allowed to cool to a safe temperature before draining. Do not overfill
oil bucket. All spills onto the product and on the floor should be cleaned up imme
-
diately.
S.6.7
The appliance must not be cleaned with a jet of water or be steam cleaned.
Do not use acid or halogen-based (e.g. chlorine) descaling liquids, flammable
liquids, cleaning aids or cleaning powders.
S.6.8
Failure due to lack of proper cleaning is not covered by warranty.
S.6.9
Particular attention must be paid to cleaning the Thermostat bulb & Capillaries.
S.6.10
Take care when cleaning not to dislodge or damage thermostat sensors mounted
on the base and side of the pan.
S.6.11
If the thermostats or capillaries are damaged then do not turn the appliance on and
contact Falcon or you approved service provider to undertake the necessary repairs.
S.6.12
In the extraordinary event that the oil level sensor does come into contact with
fire the probe should be replaced.
S.6.13
To obtain maximum performance from this unit regular servicing of the appliance
should be undertaken to ensure correct operation, it is functioning as intended, and
safe to use. We recommend servicing in accordance with SFG20 Maintenance
Schedules and as a minimum, after 2,500 hours of use, or annually, whichever comes
first and that a maintenance contract be arranged with an appointed service contact.
Visits may then be made at agreed intervals to carry out adjustments and repairs.
S.6.14
During Servicing of the appliance, where applicable, please ensure seals are
checked. If the integrity of the seal is compromised, it must be replaced.
Содержание E3840
Страница 20: ...16 5 0 CRITICAL DIMENSIONS Figure 7 Critical dimensions...
Страница 30: ...11 0 WIRING DIAGRAMS 11 1 E3840 Wiring diagram 25...
Страница 31: ...26 11 2 E3840 Circuit diagram...
Страница 32: ...27 11 3 E3840X Wiring diagram...
Страница 33: ...27 11 4 E3840X Circuit diagram...
Страница 34: ...27 11 5 E3840F Wiring diagram...
Страница 35: ...27 11 6 E3840F Circuit diagram...
Страница 36: ...27 11 7 E3840FX Wiring diagram...
Страница 37: ...27 11 8 E3840FX Circuit diagram...