Lumina 17
Installer
32
6.3
Clocks
6.3.1
Timeclock
The time clock can be used to switch external equipment. One time clock can be used per house.
INSTALLER
CLOCKS
TIME CLOCKS
TIME CLOCK
Description
Setting of the name of the function.
Time clock type
Setting indicating how the user can use the clock:
•
ON/OFF
: User enters on/off times.
•
ON/DURATION
: User enters time and duration of activation.
Time clock relay
Setting for the analogue output address (choice
LINEAR
) or relay output (choice
RELAY
).
Relay type
Setting of the passive (not controlled) relay status.
•
N.O.
(normally open) if it makes no contact.
•
N.C.
(normally closed) if it makes contact.
6.3.2
Feedclock
INSTALLER
CLOCKS
TIME CLOCKS
FEED CLOCK
Description
Setting of the name of the function.
Max. run time
Setting of the maximum run time of the feed system per feeding cycle.
Sensor delay
Setting of the sensor readout delay after the start of the feeding cycle.
Address sensor input
Setting of the digital input address of the sensor. The sensor indicates that the feeding
line is full.
Address circuit relay
Setting of the digital output address of the relay to control the feeding system.